Related Experiment Video
Updated: Aug 3, 2026

Using Enzyme-based Biosensors to Measure Tonic and Phasic Glutamate in Alzheimer's Mouse Models
Published on: May 3, 2017
Electrochemical study of the effect of radiofrequency on glutamate oxidase activity using a glutamate oxidase-based
Faezeh Faraji1, Hassan Tavakoli2, Mahvash Jafari3
1Department of Biology, Faculty of Basic Sciences, Science and Research Branch, Islamic Azad University, Tehran, Iran.
Abstract:
A biosensor based on glutamate oxidase (GluOx) was developed to measure glutamate concentration. The main function of this type of biosensor is related to the structure and catalytic activity of GluOx. Since radiofrequency, as the widest spectrum of electromagnetic fields, can affect the catalytic activity and structure of GluOx, in this study, the effect of these fields on the analytical parameters of the fabricated biosensor was investigated. To build the biosensor a sol-gel solution of chitosan and native GluOx were prepared and then immobilized on the surface of the platinum electrode. Similarly, to investigate the effect of radiofrequency fields on the analytical parameters of the biosensor, instead of the native GluOx, irradiated GluOx was used to build the biosensor. To evaluate the biosensor responses, cyclic voltammetry experiments were performed and voltammograms were considered as biosensor responses. To determine the analytical parameters including detection limit, linear range, and saturation region of the responses, calibration curves were drawn for each of the biosensors. Also the long-term stability and selectivity of the fabricated biosensor were evaluated. Thereafter, the optimum pH and temperature for each of these two biosensors were examined. The results showed that radiofrequency waves harmed the detection and response of biosensors in the saturation region, while they had little effect on the linear region. Such results could be due to the effect of radiofrequency waves on the structure and function of glutamate oxidase. In general, the results indicate that when a glutamate oxidase-based biosensor is used to measure glutamate in radiofrequency fields, corrective coefficients for this type of biosensor should be considered to accurately measure glutamate concentration.
More Related Videos
10:23Measuring In Vivo Changes in Extracellular Neurotransmitters During Naturally Rewarding Behaviors in Female Syrian Hamsters
Published on: September 12, 2017
09:33Imaging Approaches to Assessments of Toxicological Oxidative Stress Using Genetically-encoded Fluorogenic Sensors
Published on: February 7, 2018