Related Experiment Video
Updated: Jul 29, 2025

Laser-heating and Radiance Spectrometry for the Study of Nuclear Materials in Conditions Simulating a Nuclear Power Plant Accident
Published on: December 14, 2017
Optimisation of gamma spectrometry measurements in atmosphere during nuclear emergencies
Mauro Magnoni1, Stefano Bertino1, Luca Bellina1
1Department of Physical and Technological Risks, ARPA Piemonte, Via Jervis, 30, Ivrea (TO), Italy.
Abstract:
During emergencies following a major nuclear accident a prompt and accurate characterisation of the radioactive cloud is one of the main task of any radioactivity monitoring system. This task is usually performed by means of γ-spectrometry High Purity Germanium (HPGe) measurements on atmospheric particulate samples gathered by means of high-volume pumps. The key parameters describing the performances of a monitoring system are the Minimum Detectable Activities (MDAs) of the most relevant radionuclides. These parameters depend on a number of factors related to the efficiency of the available germanium detector, the volume of air filtered by the sampling devices and the γ-decay scheme of each radionuclides as well. Besides the MDAs, another very important characteristic of a monitoring system, especially during an evolving emergency, is its capability of giving reliable results at a given and constant pace. It is therefore important to define the time resolution of the monitoring system, i.e. the minimum time needed to produce the data, namely the activity concentrations of the radionuclides in the atmosphere. The optimization of the measurements procedures are discussed in this work: in particular it is demonstrated that, being t the time resolution of the monitoring system, the lowest MDAs can be achieved with a sampling time given by (2/3)·t and a counting time of (1/3)·t. Finally, the MDAs achievable for a standard monitoring system based on a 30% HPGe detector are calculated for all the most important fission products.
Related Concept Videos
Atomic Emission Spectroscopy: Lab
Atomic Emission Spectroscopy: Overview
Atomic Emission Spectroscopy: Interference
Atomic Emission Spectroscopy: Instrumentation
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Spectroscopy: Effects of Temperature
At thermal equilibrium, the relative populations of excited and ground state atoms can be estimated using the Maxwell–Boltzmann distribution. For example, an increase in temperature...

