Related Experiment Video
Updated: Jan 7, 2026

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
The Radon Effective Dose Calculation Following the Dosimetric Approach: Examples and Challenges
Mauro Magnoni1, Enrico Chiaberto1, Massimo Faure Ragani2
1ARPA Piemonte, Department of Physical and Technological Risks, Via Jervis, 30 -10015 Ivrea (TO) - Italy.
Abstract:
With the ICRP Publication 137 dealing with the occupational intake of radionuclides, an important and crucial path toward the practical implementation of the dosimetric approach also for radon was undertaken. However, some problems and difficulties must be overcome to use this new method to estimate the effective dose of radon in real situations. Direct dosimetric calculations are often not an easy task. The ICRP Publication 137 gives some examples of this new approach by providing the coefficients of the effective dose per exposure for some typical workplaces. In this work, some practical examples of the effective dose calculation in some selected workplaces were performed, studying the most important factors affecting the results. In particular, the role of the equilibrium factor F and of the dose conversion factor (DCF) as a function of the particulate size distribution were investigated and discussed. In this context, a few direct measurements of the equilibrium factor F were done as well as an experimental supporting tool for a comprehensive dose assessment.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Biological Effects of Radiation
Dose Size and Dosing Frequency: Determination Methods
Radiation Pressure: Problem Solving
The average value of the rate of momentum transfer divided by the absorbing area represents the average force...
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Dosage Regimens: Designs and Approaches
Renal Failure: Dose Adjustments
Reduced renal clearance and elimination rate are common outcomes of renal impairment. These alterations lead to a prolonged elimination half-life and an altered apparent volume of distribution for drugs. As a result, dosage adjustments are typically necessary to maintain optimal drug levels in the body.
However, dosage adjustments...