Related Experiment Video
Updated: Jul 29, 2025

Capillary Electrophoresis Separation of Monoclonal Antibody Isoforms Using a Neutral Capillary
Published on: January 16, 2017
Utilizing Mass Spectrometry to Detect and Isotype Monoclonal Proteins in Urine: Comparison to Electrophoretic Methods
Danelle H Moonen1, Mindy Kohlhagen1, Surendra Dasari1
1Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester, MN, United States.
Background:
Matrix assisted laser desorption ionization time of flight mass spectrometry coupled to immune enrichment (MASS-FIX) as an alternative to serum immunofixation electrophoresis has demonstrated increased sensitivity in monoclonal protein (MP) detection with improved laboratory workflow. This study explored similar replacement of urine immunofixation electrophoresis (u-IFE) with urine MASS-FIX (u-MASS-FIX) by method comparison.
Methods:
Residual urine (n = 1008) from Mayo Clinic patients with a known plasma cell disease were assayed neat by u-MASS-FIX analysis. Each sample was paired with the following: u-IFE, urine total protein, urine protein electrophoresis, serum κ/λ free light chain (LC) ratio (rFLC), and serum MASS-FIX (s-MASS-FIX). Analytical sensitivities were measured in pooled urine spiked with daratumumab.
Results:
u-IFE and u-MASS-FIX had 91% agreement in determining the presence/absence of MPs (Cohen kappa = 0.8200). In discrepant cases, serum rFLC statistically aligned more closely with positive u-MASS-FIX cases than u-IFE. Patients positive by both s-MASS-FIX and u-MASS-FIX had matching MP masses (±20 daltons) in 94% of cases. The u-MASS-FIX spectra further identified κ/λ LC fragments and glycosylated LCs not appreciated on u-IFE. The unconcentrated u-MASS-FIX limit of detection of 0.156 mg/mL was determined equivalent to 100× concentrated u-IFE.
Conclusion:
u-MASS-FIX is a reliable alternative to u-IFE with the added benefits of LC glycosylation detection and MP mass tracking between serum and urine. Furthermore, u-MASS-FIX is performed using neat urine. Eliminating the need to concentrate urine for u-IFE has potential to increase productivity by decreasing labor minutes per test.
Related Concept Videos
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
MALDI-TOF Mass Spectrometry
Matrix-assisted laser desorption ionization (MALDI) is a commonly...
Western Blotting
The technique begins with separating proteins from the sample using sodium dodecyl sulfate-polyacrylamide gel electrophoresis (SDS-PAGE), followed by protein transfer, immunoblotting, and finally, protein detection.
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...

