Related Experiment Video
Updated: Jul 29, 2025

Tilt Testing with Combined Lower Body Negative Pressure: a "Gold Standard" for Measuring Orthostatic Tolerance
Published on: March 21, 2013
Detecting Orthostatic Intolerance in Long COVID in a Clinic Setting
Robert Oliver Isaac1,2,3, Joanna Corrado1,2,3, Manoj Sivan1,2,3
1National Demonstration Centre for Rehabilitation, Leeds Teaching Hospitals NHS Trust, Leeds LS7 4SA, UK.
Introduction:
A likely mechanism of Long COVID (LC) is dysautonomia, manifesting as orthostatic intolerance (OI). In our LC service, all patients underwent a National Aeronautics and Space Administration (NASA) Lean Test (NLT), which can detect OI syndromes of Postural Tachycardia Syndrome (PoTS) or Orthostatic Hypotension (OH) in a clinic setting. Patients also completed the COVID-19 Yorkshire Rehabilitation Scale (C19-YRS), a validated LC outcome measure. Our objectives in this retrospective study were (1) to report on the findings of the NLT; and (2) to compare findings from the NLT with LC symptoms reported on the C19-YRS.
Methods:
NLT data, including maximum heart rate increase, blood pressure decrease, number of minutes completed and symptoms experienced during the NLT were extracted retrospectively, together with palpitation and dizziness scores from the C19-YRS. Mann-Witney U tests were used to examine for statistical difference in palpitation or dizziness scores between patients with normal NLT and those with abnormal NLT. Spearman's rank was used to examine the correlation between the degree of postural HR and BP change with C19-YRS symptom severity score.
Results:
Of the 100 patients with LC recruited, 38 experienced symptoms of OI during the NLT; 13 met the haemodynamic screening criteria for PoTS and 9 for OH. On the C19-YRS, 81 reported dizziness as at least a mild problem, and 68 for palpitations being at least a mild problem. There was no significant statistical difference between reported dizziness or palpitation scores in those with normal NLT and those with abnormal NLT. The correlation between symptom severity score and NLT findings was <0.16 (poor).
Conclusions:
We have found evidence of OI, both symptomatically and haemodynamically in patients with LC. The severity of palpitations and dizziness reported on the C19-YRS does not appear to correlate with NLT findings. We would recommend using the NLT in all LC patients in a clinic setting, regardless of presenting LC symptoms, due to this inconsistency.
More Related Videos
14:52Computerized Dynamic Posturography for Postural Control Assessment in Patients with Intermittent Claudication
Published on: December 11, 2013
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
Related Concept Videos
Hypertension III: Clinical Manifestations and Diagnostic Studies
Irritable Bowel Syndrome II: Clinical Features and Diagnostic Evaluation
Irritable Bowel Syndrome (IBS) is classified into subtypes based on the predominant bowel habits as determined by the Bristol Stool Form Scale (BSFS). The subtypes are:
Chronic Obstructive Pulmonary Disease-IV: Assessement and Diagnostic Studies
Medical History
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Exercise Stress Test
Exercise stress testing, commonly known as a treadmill test, is a noninvasive procedure used to evaluate cardiovascular function and diagnose heart conditions.
Definition
An exercise stress test measures the heart's response to exertion using a treadmill or stationary bicycle. Chest electrodes record the heart's electrical activity through an ECG, and blood pressure is monitored regularly.
Purposes