Related Experiment Video
Updated: Jun 24, 2026

Endoscopic Ultrasound-Guided Biliary Drainage: Endoscopic Ultrasound-Guided Hepaticogastrostomy in Malignant Biliary Obstruction
Published on: March 25, 2022
Efficacy of a Newly Developed Guidewire for Selective Biliary Cannulation: A Multicenter Randomized Controlled Trial
Sung Yong Han1, Sung Ill Jang2, Dong Hee Koh3
1Department of Internal Medicine, Pusan National University School of Medicine, Biomedical Research Institute, Pusan National University Hospital, Busan 49421, Republic of Korea.
A new guidewire for biliary cannulation showed similar success rates but increased ampulla contacts and cannulation time compared to conventional guidewires. Its properties include higher friction and lower stiffness, impacting its clinical effectiveness.
Area of Science:
- Gastroenterology
- Endoscopic retrograde cholangiopancreatography (ERCP)
- Medical device development
Background:
- Guidewires are crucial for selective biliary cannulation during ERCP.
- Different guidewires possess unique properties influencing their efficacy.
- A novel 0.025-inch guidewire was developed for improved biliary access.
Purpose of the Study:
- To measure the physical properties of a new guidewire (NGW).
- To compare the NGW with a conventional guidewire (CGW) in terms of basic properties.
- To evaluate the clinical effectiveness of the NGW for selective biliary cannulation.
Main Methods:
- A randomized controlled trial involving 190 patients across five hospitals.
- Patients were assigned to either the NGW group (n=95) or CGW group (n=95).
- Primary outcome: selective biliary cannulation rate in naive papillae; Secondary outcomes: guidewire properties and cannulation parameters.
Main Results:
- No significant difference in cannulation success rates (75.8% NGW vs. 84.2% CGW, p=0.102) or adverse events.
- NGW group experienced more ampulla contacts (2.58 vs. 2.02, p=0.011) and longer cannulation times (216.5s vs. 135.1s, p=0.016).
- NGW exhibited higher maximum friction, lower stiffness, and better elastic resiliency compared to CGW.
Conclusions:
- The newly developed guidewire has distinct physical properties (high friction, low stiffness).
- Clinically, it achieved comparable success and safety rates to conventional guidewires.
- Increased ampulla contacts and cannulation time suggest potential challenges in its application.
Related Concept Videos
Randomized Experiments
Simple randomization
Simple...
Bioavailability Study Design: Single Versus Multiple Dose Studies
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
Bioequivalence Experimental Study Designs: Repeated Measures, Cross-Over, Carry-Over, and Latin Square Designs