Related Experiment Video
Updated: Jul 29, 2025

Force System with Vertical V-Bends: A 3D In Vitro Assessment of Elastic and Rigid Rectangular Archwires
Published on: July 24, 2018
Thermal Programming of Commercially Available Orthodontic NiTi Archwires
Andrea Wichelhaus1, Amelie Mehnert1, Thomas Stocker1
1Department of Orthodontics and Dentofacial Orthopaedics, University Hospital, LMU Munich, Goethe-Strasse 70, 80336 Munich, Germany.
Abstract:
The shape of superelastic Nickel-Titanium (NiTi) archwires can be adjusted with thermal treatments using devices such as the Memory-MakerTM (Forestadent), which potentially affects their mechanical properties. The effect of such treatments on these mechanical properties was simulated by means of a laboratory furnace. Fourteen commercially available NiTi wires (0.018″ × 0.025″) were selected from the manufacturers American Orthodontics, Dentaurum, Forestadent, GAC, Ormco, Rocky Mountain Orthodontics and 3M Unitek. Specimens were heat treated using different combinations of annealing duration (1/5/10 min) and annealing temperature (250-800 °C) and investigated using angle measurements and three-point bending tests. Complete shape adaptation was found at distinct annealing durations/temperatures for each wire ranging between ~650-750 °C (1 min), ~550-700 °C (5 min) and ~450-650 °C (10 min), followed by a loss of superelastic properties shortly afterwards at ~750 °C (1 min), ~600-650 °C (5 min) and ~550-600 °C (10 min). Wire-specific working ranges (complete shaping without loss of superelasticity) were defined and a numerical score (e.g., stable forces) was developed for the three-point bending test. Overall, the wires Titanol Superelastic (Forestadent), Tensic (Dentaurum), FLI CuNiTi27 (Rocky Mountain Orthodontics) and Nitinol Classic (3M Unitek) proved to be the most user-friendly. Thermal shape adjustment requires wire-specific working ranges to allow complete shape acceptance and high scores in bending test performance to ensure permanence of the superelastic behaviour.
Related Concept Videos
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...

