Related Experiment Video
Updated: Jul 29, 2025

18F-Labeling of Radiotracers Functionalized with a Silicon Fluoride Acceptor SiFA for Positron Emission Tomography
Published on: January 11, 2020
Synthesis, Fluorine-18 Radiolabeling, and In Vivo PET Imaging of a Hydrophilic Fluorosulfotetrazine
Jason Beaufrez1,2, Stéphane Guillouet1, Yann Seimbille2
1UAR 3408, CNRS, CEA, Unicaen, Cyceron, Bd Henri Becquerel, 14074 Caen, France.
Abstract:
The development of 18F-fluorotetrazines, suitable for the radiolabeling of biologics such as proteins and antibodies by IEDDA ligation, represents a major challenge, especially for pre-targeting applications. The hydrophilicity of the tetrazine has clearly become a crucial parameter for the performance of in vivo chemistry. In this study, we present the design, the synthesis, the radiosynthesis, the physicochemical characterization, the in vitro and in vivo stability, as well as the pharmacokinetics and the biodistribution determined by PET imaging in healthy animals of an original hydrophilic 18F-fluorosulfotetrazine. This tetrazine was prepared and radiolabelled with fluorine-18 according to a three-step procedure, starting from propargylic butanesultone as the precursor. The propargylic sultone was converted into the corresponding propargylic fluorosulfonate by a ring-opening reaction with 18/19F-fluoride. Propargylic 18/19F-fluorosulfonate was then subject to a CuACC reaction with an azidotetrazine, followed by oxidation. The overall automated radiosynthesis afforded the 18F-fluorosulfotetrazine in 29-35% DCY, within 90-95 min. The experimental LogP and LogD7.4 values of -1.27 ± 0.02 and -1.70 ± 0.02, respectively, confirmed the hydrophilicity of the 18F-fluorosulfotetrazine. In vitro and in vivo studies displayed a total stability of the 18F-fluorosulfotetrazine without any traces of metabolization, the absence of non-specific retention in all organs, and the appropriate pharmacokinetics for pre-targeting applications.
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
![Automated Radiochemical Synthesis of [18F]3F4AP: A Novel PET Tracer for Imaging Demyelinating Diseases](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F55537.jpg&w=3840&q=50)
![Microwave-assisted One-pot Synthesis of N-succinimidyl-4-[18F]fluorobenzoate [18F]SFB](/_next/image?url=https%3A%2F%2Fcloudfront.jove.com%2FCDNSource%2Fteasers%2F2755.jpg&w=3840&q=50)