Applying expanded metal mesh for outdoor shades in outdoor thermal environments
Shing-Ru Yang1, Shih-Tang Lan2, Yi-Ting Wu2
1Department of Interior Design, Tainan University of Technology, No. 529, Zhongzheng Rd., Yongkang District, Tainan, 710, Taiwan. t60095@gm.tut.edu.tw.
Abstract:
This study investigated the applicability of expanded metal meshes (EMMs) in horizontal shading devices. We performed simulations and experiments with EMMs with different opening ratios and directions. We established various experimental and control groups to measure air temperature, surface temperature, and black globe temperature. After the comparison of simulation and experimental data, we used Grasshopper to simulate long-term climate situations. The research results can serve as reference for users in Tainan and provide customized suggestions. The findings can serve as a paradigm for parametric design to analyze EMMs. In design projects involving outdoor horizontal shading devices, these results can be used in the design phase for evaluation. Full-day measurements revealed that EMMs with small openings exhibited favorable shading effects. In the Tainan area, we suggest using north-facing EMMs; in our simulations result, 70% of sunshine did not pass through the mesh in a day. For shading equipment in the morning, west-facing EMMs should be used because they blocked 50-90% of sunshine. For recreational areas in the afternoon and evening, east-facing EMMs can block 50-90% of sunshine after noon. In Taiwan, south-facing EMMs are not advised because their shading performance is suboptimal in the morning and afternoon.
More Related Videos
Related Concept Videos
Transmission Line Design Considerations
Masonry in Cold and Hot Weather Conditions
Other key practices include keeping masonry units...
Ferrocement
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
Thermal Insulation in Masonry Walls
External insulation can be applied using an Exterior Insulation and Finish System (EIFS), which involves affixing panels of plastic foam to the wall and covering them with a polymeric stucco reinforced with glass fiber mesh....