Related Experiment Video
Updated: Jul 28, 2025

Contrast Enhanced Vessel Imaging using MicroCT
Published on: January 27, 2011
Dual-contrast photon-counting micro-CT using iodine and a novel bismuth-based contrast agent
Carlo Amato1,2, Markus Susenburger1,3, Samuel Lehr1,3
1Division of X-Ray Imaging and Computed Tomography, German Cancer Research Center (DKFZ), D-69120 Heidelberg, Germany.
Abstract:
Objectives.To characterize for the first timein vivoa novel bismuth-based nanoparticular contrast agent developed for preclinical applications. Then, to design and testin vivoa multi-contrast protocol for functional cardiac imaging using the new bismuth nanoparticles and a well-established iodine-based contrast agent.Approach.A micro-computed tomography scanner was assembled and equipped with a photon-counting detector. Five mice were administered with the bismuth-based contrast agent and systematically scanned over 5 h to quantify the contrast enhancement in relevant organs of interest. Subsequently, the multi-contrast agent protocol was tested on three mice. Material decomposition was performed on the acquired spectral data to quantify the concentration of bismuth and iodine in multiple structures, e.g. the myocardium and vasculature.Main results.In the vasculature, the bismuth agent provides a peak enhancement of 1100 HU and a half-life of about 260 min. After the injection, it accumulates in the liver, spleen and intestinal wall reaching a CT value of 440 HU about 5 h post injection. Phantom measurements showed that the bismuth provides more contrast enhancement than iodine for a variety of tube voltages. The multi-contrast protocol for cardiac imaging successfully allowed the simultaneous decomposition of the vasculature, the brown adipose tissue and the myocardium.Significance.The new bismuth-based contrast agent was proven to have a long circulation time suitable for preclinical applications and to provide more contrast than iodine agents. The proposed multi-contrast protocol resulted in a new tool for cardiac functional imaging. Furthermore, thanks to the contrast enhancement provided in the intestinal wall, the novel contrast agent may be used to develop further multi contrast agent protocols for abdominal and oncological imaging.
More Related Videos
08:13In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
08:41Novel In Vivo Micro-Computed Tomography Imaging Techniques for Assessing the Progression of Non-Alcoholic Fatty Liver Disease
Published on: March 24, 2023
Related Concept Videos
Radiological Investigation I: X-ray and CT
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Imaging Studies III: Computed Tomography
Imaging Studies II: Positron Emission Tomography and Scintigraphy