Related Experiment Video
Updated: Jul 28, 2025

High Frequency Ultrasound for the Analysis of Fetal and Placental Development In Vivo
Published on: November 8, 2018
Fluid-structure interaction analysis of amniotic fluid with fetus and placenta inside uterus exposed to military
Jonathan Arias1, Gregory Kurgansky1, Ong Chi Wei2
1New York Institute of Technology, College of Osteopathic Medicine, Old Westbury, 11568, New York, USA.
Introduction:
Pregnancy-related trauma is one of the leading causes of morbidity and mortality in pregnant women and fetuses. The fetal response to injury is largely dependent on the timing of fetal presentation and the underlying pathophysiology of the trauma. The optimal management of pregnant patients who have suffered an obstetric emergency depends on clinical assessment and understanding of the placental implantation process, which can be difficult to perform during an emergency. Understanding the mechanisms of traumatic injuries to the fetus is crucial for developing next-generation protective devices.
Methods:
This study aimed to investigate the effect of amniotic fluid on mine blast on the uterus, fetus, and placenta via computational analysis. Finite element models were developed to analyze the effects of explosion forces on the uterus, fetus, and placenta, based on cadaveric data obtained from the literature. This study uses computational fluid-structure interaction simulations to study the effect of external loading on the fetus submerged in amniotic fluid inside of the uterus.
Results:
Computational fluid-structure interaction simulations are used to study the effect of external loading on the fetus/placenta submerged in amniotic fluid inside the uterus. Cushioning function of the amniotic fluid on the fetus and placenta is demonstrated. The mechanism of traumatic injuries to the fetus/placenta is shown.
Discussion:
The intention of this research is to understand the cushioning function of the amniotic fluid on the fetus. Further, it is important to make use of this knowledge in order to ensure the safety of pregnant women and their fetuses.
More Related Videos
06:20Author Spotlight: Development of an Automated Camera-Based System for Real-Time Blast Overpressure Monitoring and TBI Risk Assessment in Military Training
Published on: December 6, 2024
07:34Fetal Mouse Cardiovascular Imaging Using a High-frequency Ultrasound 30/45MHZ System
Published on: May 5, 2018
Related Concept Videos
Cleavage and Blastulation
Fetal Circulation
Two umbilical arteries transport blood from the fetus to the placenta. At the placenta, the blood absorbs oxygen and nutrients while simultaneously eliminating waste products. This oxygen-enriched and nutrient-rich blood then returns to the fetus through one...