Diffuse Reflectance Spectroscopy: Getting the Capillary Refill Test Under One's Thumb
Published on: December 2, 2017
Cut-Off Value of Capillary Refill Time for Peripheral Circulatory Failure Diagnosis
Masayoshi Shinozaki1, Taka-Aki Nakada2, Daiki Saito2
1Department of Medical Engineering, Graduate School of Science and Engineering, Chiba University, Chiba, Japan.
Introduction:
Capillary refill time (CRT) is an indicator of peripheral circulation and is recommended in the 2021 guidelines for treating and managing sepsis.
Study Objective:
This study developed a portable device to realize objective CRT measurement. Assuming that peripheral blood flow obstruction by the artery occlusion test (AOT) or venous occlusion test (VOT) increases the CRT, the cut-off value for peripheral circulatory failure was studied by performing a comparative analysis with CRT with no occlusion test (No OT).
Methods:
Fourteen (14) healthy adults (age: 20-26 years) participated in the study. For the vascular occlusion test, a sphygmomanometer was placed on the left upper arm of the participant in the supine position, and a pressure of 30mmHg higher than the systolic pressure was applied for AOT, a pressure of 60mmHg was applied for VOT, respectively, and no pressure was applied for No OT. The CRT was measured from the index finger of the participant's left hand.
Results:
Experimental results revealed that CRT was significantly longer in the AOT and did not differ significantly in the VOT. The cut-off value for peripheral circulatory failure was found to be 2.88 seconds based on Youden's index by using receiver operating characteristic (ROC) analysis with AOT as positive and No OT as negative.
Conclusion:
Significant results were obtained in a previous study on the evaluation of septic shock patients when CRT > three seconds was considered abnormal, and the cut-off value for peripheral circulatory failure in the current study validated this.
Related Concept Videos
Assessment of the Cardiovascular System III: Palpation
Jugular Venous Pressure (JVP) Measurement
Position the patient at a thirty- to forty-five-degree angle or in a semi-fowler's position. Look for the highest point of pulsation in the internal jugular vein and measure the vertical distance to the angle of Loius or sternal angle. A normal JVP is 3-4 cm above...
Cardiovascular System Abnormal Findings I: Inspection and Palpation
Abnormal findings observed during an inspection
Peripheral Arterial Disease II: Clinical Manifestations and Diagnostic Evaluation
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Pulse
The pulse serves as a clinical...