Related Experiment Video
Updated: Jul 27, 2025

Improved Registration of 3D CT Angiography with X-ray Fluoroscopy for Image Fusion During Transcatheter Aortic Valve Implantation
Published on: June 3, 2018
Operator Radiation Exposure During Transfemoral Transcatheter Aortic Valve Replacement
Sunny Goel1,2, Richard Casazza2, Ravi Teja Pasam3
1Department of Cardiology, Mount Sinai Medical Center, New York, New York, USA.
Background:
The level of radiation exposure received by operators performing transcatheter aortic valve replacement (TAVR) is not well investigated. The aim of this study is to measure the amount of radiation received by operators performing transfemoral TAVR and to identify various patient and procedural characteristics associated with increased radiation exposure.
Methods:
Primary (operator 1) and secondary (operator 2) operators' equivalent radiation doses in micro Sieverts (µSv) were calculated prospectively using real-time radiation dosimeters for a total of 140 consecutive transfemoral TAVRs. Corresponding eye and thorax radiation exposures between the operators were compared. Associations between various patient and procedural characteristics and the radiation exposure were tested using the t-test and Wilcoxon Mann-Whitney rank-sum test with Monte Carlo estimation. Multivariable regression analysis was also conducted.
Results:
Operator 1 had significantly higher cumulative equivalent radiation exposure than operator 2 (86 µSv vs 38 µSv, p-value: <0.0001) which was consistent at the level of the thorax (67 µSv vs 22 µSv, p-value: <0.0001), but not at the level of the eye (16.5 µSv vs 15 µSv, p-value: 0.30). On multivariable analysis, patient obesity and intraprocedural complications were associated with higher radiation exposure to both operators. Ad hoc percutaneous coronary intervention led to excessive radiation exposure to the secondary operator.
Conclusions:
Transfemoral TAVR is associated with a modest amount of radiation exposure to operators and is significantly higher for the primary operator than for the secondary operator.
More Related Videos
13:48Reduction of Radiation Exposure during Endovascular Treatment of Peripheral Arterial Disease Combining Fiber Optic RealShape Technology and Intravascular Ultrasound
Published on: April 21, 2023
05:31Transradial Access Chemoembolization for Hepatocellular Carcinoma Patients
Published on: September 20, 2020
Related Concept Videos
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...