Detection and Prediction of the Early Thermal Runaway and Control of the Li-Ion Battery by the Embedded Temperature
Hengyi Zhang1, Xiaoshan Zhang1, Wenwu Wang1
1College of Material Science and Engineering, Sichuan University, Chengdu 610064, China.
Abstract:
Sorts of Li-ion batteries (LIB) have been becoming important energy supply and storage devices. As a long-standing obstacle, safety issues are limiting the large-scale adoption of high-energy-density batteries. Strategies covering materials, cell, and package processing have been paid much attention to. Here, we report a flexible sensor array with fast and reversible temperature switching that can be incorporated inside batteries to prevent thermal runaway. This flexible sensor array consists of PTCR ceramic sensors combined with printed PI sheets for electrodes and circuits. Compared to room temperature, the resistance of the sensors soars nonlinearly by more than three orders of magnitude at around 67 °C with a 1 °C/s rate. This temperature aligns with the decomposition temperature of SEI. Subsequently, the resistance returns to normal at room temperature, demonstrating a negative thermal hysteresis effect. This characteristic proves advantageous for the battery, as it enables a lower-temperature restart after an initial warming phase. The batteries with an embedded sensor array could resume their normal function without performance compromise or detrimental thermal runaway.
More Related Videos
08:42In Situ Gas Analysis and Fire Characterization of Lithium-Ion Cells During Thermal Runaway Using an Environmental Chamber
Published on: March 31, 2023
10:36Author Spotlight: Optimization of Airflow Velocities in Battery Cooling Systems for Enhanced Thermal Performance and Reduced Energy Consumption
Published on: November 3, 2023
Related Concept Videos
Operational Amplifiers
Thermal Stress
Thermal expansion and Thermal stress: Problem Solving
To solve the problem, first, identify the known and unknown quantities. The initial length (L) of the bridge is 1275 m, the coefficient of linear expansion (α) for steel is 12 x 10-6/°C, and the change in...
Thermosensation
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...
