Related Experiment Video
Updated: Jul 27, 2025

A Low Cost Setup for Behavioral Audiometry in Rodents
Published on: October 16, 2012
A Quantitative Evaluation of the Performance of the Low-Cost AudioMoth Acoustic Recording Unit
Sam Lapp1, Nickolus Stahlman1, Justin Kitzes1
1Department of Biological Sciences, University of Pittsburgh, 103 Clapp Hall, Fifth and Ruskin Avenues, Pittsburgh, PA 15260, USA.
Abstract:
The AudioMoth is a popular autonomous recording unit (ARU) that is widely used to record vocalizing species in the field. Despite its growing use, there have been few quantitative tests on the performance of this recorder. Such information is needed to design effective field surveys and to appropriately analyze recordings made by this device. Here, we report the results of two tests designed to evaluate the performance characteristics of the AudioMoth recorder. First, we performed indoor and outdoor pink noise playback experiments to evaluate how different device settings, orientations, mounting conditions, and housing options affect frequency response patterns. We found little variation in acoustic performance between devices and relatively little effect of placing recorders in a plastic bag for weather protection. The AudioMoth has a mostly flat on-axis response with a boost above 3 kHz, with a generally omnidirectional response that suffers from attenuation behind the recorder, an effect that is accentuated when it is mounted on a tree. Second, we performed battery life tests under a variety of recording frequencies, gain settings, environmental temperatures, and battery types. We found that standard alkaline batteries last for an average of 189 h at room temperature using a 32 kHz sample rate, and that lithium batteries can last for twice as long at freezing temperatures compared to alkaline batteries. This information will aid researchers in both collecting and analyzing recordings generated by the AudioMoth recorder.
Related Concept Videos
Sampling Methods: Overview
In analytical chemistry, the choice of...
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Design Example: Vintage Mixing Console
The specifications for the pre-amplifier were clear. It needed to amplify the audio signal by a factor of 10, have an input impedance above 10...
Pulse amplitude and quality
A weak or absent pulse may indicate reduced cardiac output or poor left ventricular contraction, which can be signs of cardiovascular dysfunction or...
Sound Intensity Level
The human ear can perceive an extensive range of sound intensity, necessitating the use of the logarithmic scale to define a physical quantity—the intensity level. It is a ratio of two intensities and...

