Procedure and Key Optimization Strategies for an Automated Capillary Electrophoretic-based Immunoassay Method
Published on: September 10, 2017
Fifth Generation Quality Control of Immunoassay Parameters by Six Sigma Value
Qurat Ul Ain1, Muhammad Younas, Zujaja Hina Haroon1
1Department of Chemical Pathology, Armed Forces Institute of Pathology (AFIP), NUMS Rawalpindi, Pakistan.
Objective:
To determine the sigma value of immunoassay parameters which are within the 2Z score on external quality control (EQC).
Study Design:
A cross-sectional study. Place and Duration of the Study: Department of Chemical Pathology and Endocrinology (AFIP),non-ability ity consecutive from June to November 2022.
Methodology:
Ten immunoassay parameters were selected on the basis of the internal quality control (IQC) and external quality control (EQC) programs. The Clinical Laboratory Improvement Amendments (CLIA) is used for Total Allowable Error (TEa). Sigma value was calculated from coefficient of variation (CV) and bias, which was determined by IQC and EQC, observed for 6 subsequent months. If the sigma values are ≥6, between 3 and 5, and <3, they are classified as good, acceptable or unacceptable, respectively.
Results:
T4, prolactin, Vitamin B12 at >3 ó at IQC level 1. TSH, T3, T4, and Vitamin B12 showed that on level 2 IQC at >3 ó T3, Vitamin D at 4-5 ó level, Prolactin, FSH, and LH at 6 ó level in level 2 IQC. In the EQC program, the sigma level calculated for ten assays found that almost all parameters were at sigma >3 ó level except TSH which was at 5.8 ϭ level during June to August 2022. From September to November 2022, all parameters at >3 ó level except for TSH, growth hormone, FSH, LH, and Vitamin b12 which showed at 4.4 ó level.
Conclusion:
Most of the immunoassay parameters show good performance in the EQC program and at both levels of IQC level with sigma value 4-5.
Key Words:
Bias, Six sigma, Key performance indicators, External quality control.
Related Concept Videos
Data Validation
Key parameters for method validation include:
Quality Assurance
Quality Control
Quality control helps track data, visualize trends, and identify variations, making it easier to detect deviations that may affect the accuracy of an analysis. One way to do this is by generating a quality control chart, which...
Contaminants and Errors
Another key consideration is determining the appropriate number of samples required to...
Testing a Claim about Standard Deviation
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...