Related Experiment Video
Updated: Jul 27, 2025

Mimicking and Measuring Occlusal Erosive Tooth Wear with the "Rub&Roll" and Non-contact Profilometry
Published on: February 2, 2018
Wear effects between polymethyl methacrylate occlusal splints and opposing dentin surfaces during bruxism mimicking
Prangtip Potewiratnanond1, Cholakorn Ekrojanakul2, Tatcharee Harikul2
1Department of Occlusion, Faculty of Dentistry, Chulalongkorn University, Bangkok, Thailand. Prangtip.p@chula.ac.th.
Objectives:
To compare the surface wear rate between polymethyl methacrylate (PMMA)-based occlusal splints and opposing dentin-exposed teeth in bruxism simulating models.
Materials And Methods:
PMMA-based occlusal splints and extracted premolars were tested on a chewing stimulator at 30,000 or 60,000 cycles. Dentin wear was measured under a stereomicroscope and PMMA wear was determined with an optical profilometer. In addition, wear surface topography was assessed and quantified by scanning electron microscopy (SEM).
Results:
Wear rate of PMMA was significantly greater (11 times) than that of dentin specimens at 60,000 cycles, though these findings were not observed at 30,000 cycles. When comparing wear rates within each group at different duration cycles, PMMA surfaces exhibited an average wear rate 1.4 times higher with high duration cycles, while dentin surfaces displayed a marginal decrease in wear. In SEM micrographs, PMMA surfaces displayed more wear abrasion lines with higher duration cycles. However, dentin surfaces did not exhibit major differences between low and high duration cycles.
Conclusion:
Wear rate on PMMA-based occlusal splints remarkably increases upon high chewing cycles mimicking bruxism comparing with the rate on dentin. Hence, it is reasonable for bruxing patients to wear single-arch PMMA-based occlusal splints to protect opposing dentin-exposed teeth.
More Related Videos
07:42Quasistatic Mechanical Testing for Computer-Aided Design and Manufacturing Occlusal Veneers Cemented to Milled Dentin Analog Material
Published on: December 20, 2024
07:09In situ Compressive Loading and Correlative Noninvasive Imaging of the Bone-periodontal Ligament-tooth Fibrous Joint