Related Experiment Video
Updated: Jul 27, 2025

A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Strategies for calculating contrast media dose for chest CT
Mette Karen Henning1,2, Catherine Gunn3, Juan Arenas-Jiménez4,5,6
1Faculty of Health Sciences, Department of Life Sciences and Health, Oslo Metropolitan University, Oslo, Norway.
Background:
Total body weight (TBW) is a frequently used contrast media (CM) strategy for dose calculation in enhanced CT, yet it is suboptimal as it lacks consideration of patient characteristics, such as body fat percentage (BFP) and muscle mass. Alternative CM dosage strategies are suggested by the literature. Our objectives were to analyze the CM dose impact when adjusting to body composition using methods of obtaining lean body mass (LBM) and body surface area (BSA) along with its correlation with demographic factors in contrast enhanced chest CT examinations.
Methods:
Eighty-nine adult patients referred for CM thoracic CT were retrospectively included, categorized as either normal, muscular, or overweight. Patient body composition data was used to calculate the CM dose according to LBM or BSA. LBM was calculated with the James method, Boer method, and bioelectric impedance (BIA). BSA was calculated using the Mostellar formula. We then correlated the corresponding CM doses with demographic factors.
Results:
BIA demonstrated the highest and lowest calculated CM dose in muscular and overweight groups respectively, compared to other strategies. For the normal group, the lowest calculated CM dose was achieved using TBW. The calculated CM dose was more closely correlated with BFP using the BIA method.
Conclusions:
The BIA method is more adaptive to variations in patient body habitus especially in muscular and overweight patients and is most closely correlated to patient demographics. This study could support utilizing the BIA method for calculating LBM for a body-tailored CM dose protocol for enhanced chest CT examinations.
Relevance Statement:
The BIA-based method is adaptive to variations in body habitus especially in muscular and overweight patients and is closely correlated to patient demographics for contrast-enhanced chest CT.
Key Points:
• Calculations based on BIA showed the largest variation in CM dose. • Lean body weight using BIA demonstrated the strongest correlation to patient demographics. • Lean body weight BIA protocol may be considered for CM dosing in chest CT.
Related Concept Videos
Radiological Investigation I: X-ray and CT
Imaging Studies III: Computed Tomography
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...