Related Experiment Video
Updated: Jul 27, 2025

Disposable Dosators for Pulmonary Insufflation of Therapeutic Agents to Small Animals
Published on: March 30, 2017
Quantifying strategies to minimize aerosol dispersion in dental clinics
Shamudra Dey1, Maryam Tunio2, Louis C Boryc2
1Joint Department of Biomedical Engineering, Marquette University, Medical College of Wisconsin, Milwaukee, 53226 USA.
Abstract:
Many dental procedures are aerosol-generating and pose a risk for the spread of airborne diseases, including COVID-19. Several aerosol mitigation strategies are available to reduce aerosol dispersion in dental clinics, such as increasing room ventilation and using extra-oral suction devices and high-efficiency particulate air (HEPA) filtration units. However, many questions remain unanswered, including what the optimal device flow rate is and how long after a patient exits the room it is safe to start treatment of the next patient. This study used computational fluid dynamics (CFD) to quantify the effectiveness of room ventilation, an HEPA filtration unit, and two extra-oral suction devices to reduce aerosols in a dental clinic. Aerosol concentration was quantified as the particulate matter under 10 µm (PM10) using the particle size distribution generated during dental drilling. The simulations considered a 15 min procedure followed by a 30 min resting period. The efficiency of aerosol mitigation strategies was quantified by the scrubbing time, defined as the amount of time required to remove 95% of the aerosol released during the dental procedure. When no aerosol mitigation strategy was applied, PM10 reached 30 µg/m3 after 15 min of dental drilling, and then declined gradually to 0.2 µg/m3 at the end of the resting period. The scrubbing time decreased from 20 to 5 min when the room ventilation increased from 6.3 to 18 air changes per hour (ACH), and decreased from 10 to 1 min when the flow rate of the HEPA filtration unit increased from 8 to 20 ACH. The CFD simulations also predicted that the extra-oral suction devices would capture 100% of the particles emanating from the patient's mouth for device flow rates above 400 L/min. In summary, this study demonstrates that aerosol mitigation strategies can effectively reduce aerosol concentrations in dental clinics, which is expected to reduce the risk of spreading COVID-19 and other airborne diseases.
Related Concept Videos
Transmission-based Precautions II: Airborne and Protective Environment
Airborne precautions:
Use airborne precautions when treating patients known or suspected to have diseases that spread through the air—for example, tuberculosis or measles. These organisms are present in smaller droplets expelled by an infected person and...
Inhaled Medications
Standard Precaution
Hand hygiene is the most crucial means to prevent the transmission of disease. Employers are legally required to provide their workers with personal protective equipment (PPE) to minimize exposure or contact with...
Transmission-based Precautions I: Contact, Enteric, and Droplets
Contact Precautions:
Contact precautions are the measures taken to prevent the transmission of infectious agents, especially epidemiologically important microorganisms such as MRSA or influenza, primarily transmitted through direct or indirect contact with an...
Healthcare Associated Infections II: Preventive Measures
The best practices for preventing healthcare-associated infections include hand hygiene, patient risk...
Cardiopulmonary Resuscitation II: ACLS Airway Management

