Comparison of positive pressure extubation with traditional extubation in critically ill patients - a randomised
Ajeetviswanath Thanjavur Prabhakaran1, Darlong Vanalal1, Kapil Soni2
1Department of Anesthesiology, Pain Medicine and Critical Care, All India Institute of Medical Sciences, New Delhi, India.
Background:
Two extubation methods are commonly used in the intensive care unit (ICU): the traditional method with endotracheal suctioning and the positive- pressure method without suctioning. Better physiological outcomes were found in lab studies using the latter, as the air passing between the endotracheal tube and the larynx pushes out the collected subglottic secretions, which can be suctioned.
Methods:
70 mechanically ventilated patients in a tertiary ICU were randomised into 2 groups of 35 patients each. At the end of the spontaneous breathing trial (SBT), the positive pressure extubation (PPE) group was given a pressure support of 15 cm H 2 O and a positive end expiratory pressure of 10 cm H 2 O for 5 minutes while the other group (traditional extubation - TE) was extubated directly. We compared the lung ultrasound scores (LUS), chest X-ray findings, alveolar arterial oxygen gradient changes, adverse clinical events, ICU-free days and reintubation rates between the two groups.
Results:
Median LUS at the end of the SBT was similar between the two groups. However, the median post-extubation LUS at 30 minutes, 6 hours, 24 hours in the PPE group [5 (4-8) ( P = 0.04), 5 (3-8) ( P = 0.02), 4 (3-7) ( P = 0.02), respectively] were significantly lower compared to the TE group [6 (6-8), 6 (5-7.5), 6 (5-7.5), respectively]. There was a persistent lowering of the scores even at the end of 24 hours in the PPE group, while the percentage of patients without adverse clinical events was significantly higher (80% vs. 57.14%, P = 0.04).
Conclusions:
The study shows that positive pressure extubation is a safe procedure which improves aeration and reduces adverse events.
More Related Videos
Related Concept Videos
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Mechanical Ventilation III: Noninvasive Ventilation
Noninvasive Positive-Pressure Ventilation...
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Mechanical Ventilation I: Indication and Settings