An in-vivo validation of ESI methods with focal sources
Annalisa Pascarella1, Ezequiel Mikulan2, Federica Sciacchitano3
1CNR - IAC, Rome, Italy.
Abstract:
Electrophysiological source imaging (ESI) aims at reconstructing the precise origin of brain activity from measurements of the electric field on the scalp. Across laboratories/research centers/hospitals, ESI is performed with different methods, partly due to the ill-posedness of the underlying mathematical problem. However, it is difficult to find systematic comparisons involving a wide variety of methods. Further, existing comparisons rarely take into account the variability of the results with respect to the input parameters. Finally, comparisons are typically performed using either synthetic data, or in-vivo data where the ground-truth is only roughly known. We use an in-vivo high-density EEG dataset recorded during intracranial single pulse electrical stimulation, in which the true sources are substantially dipolar and their locations are precisely known. We compare ten different ESI methods, using their implementation in the MNE-Python package: MNE, dSPM, LORETA, sLORETA, eLORETA, LCMV beamformers, irMxNE, Gamma Map, SESAME and dipole fitting. We perform comparisons under multiple choices of input parameters, to assess the accuracy of the best reconstruction, as well as the impact of such parameters on the localization performance. Best reconstructions often fall within 1 cm from the true source, with most accurate methods hitting an average localization error of 1.2 cm and outperforming least accurate ones erring by 2.5 cm. As expected, dipolar and sparsity-promoting methods tend to outperform distributed methods. For several distributed methods, the best regularization parameter turned out to be the one in principle associated with low SNR, despite the high SNR of the available dataset. Depth weighting played no role for two out of the six methods implementing it. Sensitivity to input parameters varied widely between methods. While one would expect high variability being associated with low localization error at the best solution, this is not always the case, with some methods producing highly variable results and high localization error, and other methods producing stable results with low localization error. In particular, recent dipolar and sparsity-promoting methods provide significantly better results than older distributed methods. As we repeated the tests with "conventional" (32 channels) and dense (64, 128, 256 channels) EEG recordings, we observed little impact of the number of channels on localization accuracy; however, for distributed methods denser montages provide smaller spatial dispersion. Overall findings confirm that EEG is a reliable technique for localization of point sources and therefore reinforce the importance that ESI may have in the clinical context, especially when applied to identify the surgical target in potential candidates for epilepsy surgery.
More Related Videos
11:28Concurrent EEG and Functional MRI Recording and Integration Analysis for Dynamic Cortical Activity Imaging
Published on: June 30, 2018
07:05Correlative Optical Spectroscopy and Mass Spectrometry Imaging Methodology to Visualise Drug Distribution in a Soft Tissue Section
Published on: June 20, 2025
Related Concept Videos
Electrospray Ionization (ESI) Mass Spectrometry
ESI utilizes electrical energy to transfer ions from the liquid phase of the sample into the...
Atomic Emission Spectroscopy: Lab
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used....