Related Experiment Video
Updated: Jul 26, 2025

Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
Safety in radiation oncology (SAFRON): Learning about incident causes and safety barriers in external beam
Maryam Zarei1, Vesna Gershan1, Ola Holmberg1
1Radiation Protection of Patients Unit, Radiation Safety and Monitoring Section, Division of Radiation, Transport and Waste Safety, International Atomic Energy Agency, Vienna, Austria.
Purpose:
Safety in Radiation Oncology (SAFRON) is a reporting and learning system on radiotherapy and radionuclide therapy incidents and near misses. The primary aim of this paper is to examine whether any discernible patterns exist in the causes of reported incidents and safety barriers within the SAFRON system concerning external beam radiotherapy.
Methods And Materials:
This study focuses on external beam radiotherapy incidents, reviewing 1685 reports since the inception of SAFRON until December 2021. Reports that did not identify causes of incidents and safety barriers were excluded from the final study population.
Results:
Simple two-dimensional radiotherapy or electron beam therapy were represented by 97 reports, three-dimensional conformal radiotherapy by 39 reports, modulated arc therapy by 12 reports, intensity modulated radiation therapy by 11 reports, stereotactic radiosurgery by 4 reports, and radiotherapy with protons or other particles by 1 report, while for 92 of them, no information on treatment method had been provided. Most of the reported incidents were minor incidents and were discovered by the radiation therapist. Inadequate direction/information in staff communication was the most frequently reported cause of incident, and regular independent chart check was the most common safety barrier.
Conclusions:
The results indicate that the majority of incidents were reported by radiation therapists, and the majority of these incidents were classified as minor. Communication problems and failure to follow standards/procedures/practices were the most frequent causes of incidents. Furthermore, regular independent chart checking was the most frequently identified safety barrier.
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Nuclear Power
Nuclear Fuels
Nuclear fuel consists of a fissile isotope, such as uranium-235, which must be present in sufficient quantity to provide a...
X-ray Imaging
Barriers to Effective Communication II
Cultural barriers:
Differences in values, beliefs, religion, knowledge, and tradition can significantly impact communication. Awareness of nonverbal cues is critical, especially when conversing with a patient from a different culture. What appears appropriate in one culture may be inappropriate in another.
Semantic barriers:
As a result of their tendency to use...
Radiation: Applications
The average...