Related Experiment Video
Updated: Jul 26, 2025

Preparation, Purification, and Characterization of Lanthanide Complexes for Use as Contrast Agents for Magnetic Resonance Imaging
Published on: July 21, 2011
[New solutions for an old problem : Current developments in oral contrast agents]
Thomas Fork1,2, Ingvar Adnerhill3,4, Olof Böök4
1Emeritus aus der Abteilung Radiologie, Universitätsklinikum Lund, Malmö, Schweden. thomas.fork@lumentab.com.
Background:
Several radiological societies in Europe have so far spoken out in favor of MRI of the small intestine over CT, since MRI is said to provide more detailed image information. Due to the limited availability of MRI machines, long waiting times arise for many patients who clinically require small bowel imaging.
Objectives:
These circumstances guided our search for an improved CT technique that would provide scans that mimic the image impression of T1 sequence in MRI, i.e. with IV contrast-enhanced intestinal wall versus low/no signal lumen.
Material And Methods:
The oral use of fat or oil is poorly tolerated by patients, as is the placement of a naso-duodenal tube for air insufflation. We have now succeeded in creating a foamy drink with 44% air content, which is kept stable by protein together with buffers, and can be easily administered orally. CT with the Lumentin® beverage as bowel filling agent has been tested on healthy adult volunteers; oncology patients; and Crohn's disease patients who, for comparison, also underwent MRI of the small bowel with conventional oral contrast.
Results:
The results so far with Lumentin® show a very good distribution throughout the entire small intestine with good lumen distension, images with strongly enhanced contrast of the intestinal mucosa, and lesions that are detected at the same or increased frequency as compared with MRI. Side effects were few and mild, and overall fewer than with commonly used oral agents. Lumentin's foamy consistency was unfamiliar to a few patients, but it wasn't difficult to drink.
Conclusions:
The new and innovative luminal HU-negative contrast agent Lumentin® improves the diagnostic CT image quality. In addition, Lumentin® experimental MRI tests have provided promising results, which are currently leading to further clinical MRI studies.
More Related Videos
Related Concept Videos
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies VII: Vascular Imaging
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...