Prone position PET/CT is useful in reducing gravity-dependent opacity-related [18F]fluorodeoxyglucose uptake
Yun Hye Song1, Jung Won Moon1, Yoo Na Kim1
1Department of Radiology, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, 1 Singil-ro, Yeongdeungpo-gu, Seoul, 07441, Republic of Korea.
Objectives:
This study aimed to investigate whether performing [18F]fluorodeoxyglucose ([18F]FDG) positron emission tomography/computed tomography (PET/CT) in the prone position could reduce [18F]FDG uptake in dependent lungs.
Methods:
Patients who underwent [18F]FDG PET/CT in both supine and prone positions from October 2018 to September 2021 were reviewed retrospectively. [18F]FDG uptake of dependent and nondependent lungs was analysed visually and semi-quantitatively. A linear regression analysis was performed to examine the association between the mean standardised uptake value (SUVmean) and the Hounsfield unit (HU).
Results:
A total of 135 patients (median age, 66 years [interquartile range: 58-75 years]; 80 men) were included. Dependent lungs showed significantly higher SUVmean and HU than nondependent lungs on supine position PET/CT (sPET/CT, 0.59 ± 0.14 vs. 0.36 ± 0.09, p < 0.001; - 671 ± 66 vs. - 802 ± 43, p < 0.001, respectively) and prone position PET/CT (pPET/CT, 0.45 ± 0.12 vs. 0.42 ± 0.08, p < 0.001; - 731 ± 67 vs. - 790 ± 40, p < 0.001, respectively). Linear regression analysis revealed a strong association between the SUVmean and HU in sPET/CT (R = 0.86, p < 0.001) and moderate association in pPET/CT (R = 0.65, p < 0.001). One hundred and fifteen patients (85.2%) had visually discernible [18F]FDG uptake in the posterior lung on sPET/CT, which disappeared on pPET/CT in all but one patient (0.7%, p < 0.001).
Conclusions:
[18F]FDG uptake of the lung had moderate-to-strong associations with HU. Gravity-dependent opacity-related [18F]FDG uptake can be effectively reduced on prone position PET/CT.
Clinical Relevance Statement:
Prone position PET/CT effectively reduces gravity-dependent opacity-related [18F]fluorodeoxyglucose uptake in the lung, potentially improving diagnostic accuracy in evaluating nodules in dependent lungs and offering a more accurate assessment of lung inflammation parameters in interstitial lung disease evaluations.
Key Points:
• The study evaluated whether performing [18F]fluorodeoxyglucose ([18F]FDG) PET/CT could reduce [18F]FDG uptake in lungs. • In prone and supine position PET/CT, the [18F]FDG uptake and Hounsfield unit were moderately to strongly associated. • Prone position PET/CT can reduce gravity-dependent opacity-related [18F]FDG uptake by the posterior lung.
More Related Videos
10:02Quantification of Atherosclerotic Plaque Activity and Vascular Inflammation using [18-F] Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography FDG-PET/CT
Published on: May 2, 2012
09:21Human Brown Adipose Tissue Depots Automatically Segmented by Positron Emission Tomography/Computed Tomography and Registered Magnetic Resonance Images
Published on: February 18, 2015
Related Concept Videos
Positron Emission Tomography
One of the main requirements of a PET scan is a positron-emitting radioisotope, which is produced in a cyclotron and then attached to a substance used by the part of the body...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies III: Computed Tomography
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...