Related Experiment Video For airway management
Updated: Jul 26, 2025

Image Acquisition using Portable Sonography for Emergency Airway Management
Published on: September 28, 2022
Clinical tests for confirming tracheal intubation or excluding oesophageal intubation: a diagnostic test accuracy
J Hansel1, J A Law2, N Chrimes3
1Division of Immunology, Immunity to Infection and Respiratory Medicine, University of Manchester, Manchester, UK.
Abstract:
Unrecognised oesophageal intubation causes preventable serious harm to patients undergoing tracheal intubation. When capnography is unavailable or doubted, clinicians still use clinical findings to confirm tracheal intubation, or exclude oesophageal intubation, and false reassurance from clinical examination is a recurring theme in fatal cases of unrecognised oesophageal intubation. We conducted a systematic review and meta-analysis of the diagnostic accuracy of five clinical examination tests and the oesophageal detector device when used to confirm tracheal intubation. We searched four databases for studies reporting index clinical tests against a reference standard, from inception to 28 February 2023. We included 49 studies involving 10,654 participants. Methodological quality was overall moderate to high. We looked at misting (three studies, 115 participants); lung auscultation (three studies, 217 participants); combined lung and epigastric auscultation (four studies, 506 participants); the oesophageal detector device (25 studies, 3024 participants); 'hang-up' (two non-human studies); and chest rise (one non-human study). The reference standards used were capnography (22 studies); direct vision (10 studies); and bronchoscopy (three studies). When used to confirm tracheal intubation, misting has a false positive rate (95%CI) of 0.69 (0.43-0.87); lung auscultation 0.14 (0.08-0.23); five-point auscultation 0.18 (0.08-0.36); and the oesophageal detector device 0.05 (0.02-0.09). Tests to exclude events that invariably lead to severe damage or death must have a negligible false positive rate. Misting or auscultation have too high a false positive rate to reliably exclude oesophageal intubation and there is insufficient evidence to support the use of 'hang-up' or chest rise. The oesophageal detector device may be considered where other more reliable means are not available, though waveform capnography remains the reference standard for confirmation of tracheal intubation.
Related Concept Videos
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Cardiopulmonary Resuscitation V: Advanced Airway Management Techniques
Trachea
Anatomical Features:
Location: About half of the trachea is situated in the neck, anterior to the esophagus, and extends from the larynx (at the level of...
Endotracheal Intubation II: Nursing Management
1. Nursing Care of Patients Before Intubation
Before the endotracheal intubation procedure, nurses play an essential role in ensuring the process goes smoothly. The nurses must be familiar with intubation...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals....
Tracheostomy Decannulation
Description of the Procedure
Decannulation refers to the permanent removal of the tracheostomy tube, signaling the resolution of the condition that initially necessitated the tracheostomy. The process requires a well-coordinated interplay between...