Introduction:
Cryoablation is being used as an alternative to radiofrequency (RF) ablation for atrioventricular nodal reentrant tachycardia (AVNRT) owing to the lower risk of atrioventricular block (AVB) compared to RF ablation. Junctional rhythm often occurs during successful application of RF ablation for AVNRT. In contrast, junctional rhythm has rarely been reported to occur during cryoablation. This retrospective study evaluated the characteristics of junctional rhythm during cryoablation for typical AVNRT.
Methods And Results:
This retrospective study included 127 patients in whom successful cryoablation of typical AVNRT was performed. Patients diagnosed with atypical AVNRT were excluded. Junctional rhythm appeared during cryofreezing in 22 patients (17.3%). These junctional rhythms appeared due to cryofreezing at the successful site in the early phase within 15 s of commencement of cooling. Transient complete AVB was observed in 10 of 127 patients (7.9%), and it was noted that atrioventricular conduction improved immediately after cooling was stopped in these 10 patients. No junctional rhythm was observed before the appearance of AVB. No recurrence of tachycardia was confirmed in patients in whom junctional rhythm occurred by cryofreezing at the successful site.
Conclusion:
Occurrence of junctional rhythms during cryoablation is not so rare and can be considered a criterion for successful cryofreezing. Furthermore, junctional rhythm may be associated with low risk of recurrent tachycardia.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
06:57Ablation of Ischemic Ventricular Tachycardia Using a Multipolar Catheter and 3-dimensional Mapping System for High-density Electro-anatomical Reconstruction
Published on: January 31, 2019
Related Concept Videos
Dysrhythmias IV: Characteristics of Bradyarrhythmias
Disturbances in Heart Rhythm
Arrhythmias are categorized by their speed, rhythm, and origin. A slow...
Electrophysiology of Normal Cardiac Rhythm
Dysrhythmias II: Classification of Tachyarrhythmias
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Conduction System of the Heart
The pacemaker cells are located in two primary nodes: the sinoatrial (SA) node and the atrioventricular (AV) node. The SA node pacemaker cells can autonomously depolarize, triggering an action potential that leads to the...