Related Experiment Video
Updated: Jul 25, 2025

A Novel Method for Involving Women of Color at High Risk for Preterm Birth in Research Priority Setting
Published on: January 12, 2018
Comparison of Four Tests for Preterm Birth Prediction in Symptomatic Singleton Women: A Prospective Cohort Study
Maryam Najjarzadeh1, Sakineh Mohammad-Alizadeh-Charandabi2, Mohammad Asghari Jafarabadi3,4,5
1Department of Midwifery, Faculty of Nursing and Midwifery, Urmia University of Medical Sciences, Urmia, Iran.
Background and Purpose: It is challenging to predict preterm births accurately. We sought to compare the diagnostic performance of cervical length in predicting preterm birth to those of contraction recording in cardiotocography (CTG), cervical funneling, and Bishop score. Methods: A total of 371 women with singleton pregnancies and threatened preterm labor admitted to tertiary hospitals of northwestern Iran were included in this prospective cohort study and followed up until childbirth. Transvaginal ultrasound was utilized to assess the cervical length and funneling. Also, a CTG test and digital vaginal examination were performed. The data of 218 women were analyzed in the STATA software. The sensitivity and other diagnostic performances, and 95% confidence intervals, were reported. Results: The CTG uterine contraction recording had the highest sensitivity for predicting birth within the next 2 days, whereas a Bishop score ≥6 revealed the highest specificity, positive predictive value, and positive likelihood ratio. Inadequate cervical length for gestational age exhibited a high negative predictive value and the lowest negative likelihood ratio. Conclusion: The cervical length test has good diagnostic and prognostic performance among the four tests for preterm birth. Cervical funneling and CTG tests have poor predictive value, whereas the Bishop score has a superior diagnostic performance to the other tests.
Background and Purpose: It is challenging to predict preterm births accurately. We sought to compare the diagnostic performance of cervical length in predicting preterm birth to those of contraction recording in cardiotocography (CTG), cervical funneling, and Bishop score. Methods: A total of 371 women with singleton pregnancies and threatened preterm labor admitted to tertiary hospitals of northwestern Iran were included in this prospective cohort study and followed up until childbirth. Transvaginal ultrasound was utilized to assess the cervical length and funneling. Also, a CTG test and digital vaginal examination were performed. The data of 218 women were analyzed in the STATA software. The sensitivity and other diagnostic performances, and 95% confidence intervals, were reported. Results: The CTG uterine contraction recording had the highest sensitivity for predicting birth within the next 2 days, whereas a Bishop score ≥6 revealed the highest specificity, positive predictive value, and positive likelihood ratio. Inadequate cervical length for gestational age exhibited a high negative predictive value and the lowest negative likelihood ratio. Conclusion: The cervical length test has good diagnostic and prognostic performance among the four tests for preterm birth. Cervical funneling and CTG tests have poor predictive value, whereas the Bishop score has a superior diagnostic performance to the other tests.
More Related Videos
Related Concept Videos
Sign Test for Matched Pairs
To conduct the sign test, we first calculate the differences in...
Bonferroni Test
The means of different samples are first paired in all possible combinations.
The null hypothesis of the...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...

