Related Experiment Video
Updated: Jul 25, 2025

Real-Time Cardiac Mapping with a Noninvasive Imageless Electrocardiographic Imaging System
Published on: April 11, 2025
EDEN (Electrocardiographic Radial Depth Navigation): A Novel Approach to Navigate Inside Heart Muscle
Christopher G Bruce1, D Korel Yildirim2, Aravindan Kolandaivelu3
1Cardiovascular Branch, Division of Intramural Research, National Heart, Lung and Blood Institute, National Institutes of Health, Bethesda, Maryland, USA. Electronic address: https://twitter.com/ChrisGBruce13.
Background:
Intramyocardial guidewire navigation is a novel technique that allows free transcatheter movement within ventricular muscle. Guidewire radial depth, between endocardial and epicardial surfaces, is ambiguous by x-ray and echocardiography.
Objectives:
The aim of this study was to develop a simple tool, EDEN (Electrocardiographic Radial Depth Navigation), to indicate radial depth during intramyocardial guidewire navigation. Combined with routine imaging, EDEN facilitates a new family of intramyocardial catheter procedures to slice, reshape, pace, and ablate the heart.
Methods:
We mapped intramyocardial electrograms of left and right ventricular walls and septum during open- and closed-chest swine procedures (N = 53), including MIRTH (Myocardial Intramural Remodeling by Transvenous Tether) ventriculoplasty. We identified radial depth-dependent features on unipolar electrograms. We developed a machine learning-based classifier to indicate categorical position, and modeled the findings in silico to test understanding of the physiology.
Results:
EDEN signatures distinguished 5 depth zones throughout left and right ventricular free walls and interventricular septum. Relative ST-segment elevation magnitude best discriminated position and was maximum (40.1 ± 6.5 mV) in the midmyocardium. Subendocardial positions exhibited dominant Q waves with lower-amplitude ST segments (16.8 ± 5.8 mV), whereas subepicardial positions exhibited dominant R waves with lower-amplitude ST segments (15.7 ± 4.8 mV). EDEN was unaffected by pacing-induced left bundle branch block. ST-segment elevation declined over minutes and reappeared after submillimeter guidewire manipulation. Modeling recapitulated EDEN features. The machine learning-based classifier was 97% accurate. EDEN successfully guided MIRTH ventriculoplasty.
Conclusions:
EDEN provides a simple and reproducible real-time reflection of categorical guidewire-tip radial depth during intramyocardial guidewire navigation. Used in tandem with x-ray, EDEN enables novel, transcatheter, intramyocardial therapies such as MIRTH, SESAME (Septal Surfing Along Midline Endocardium), and cerclage ventriculoplasty.
More Related Videos
09:13Remote Magnetic Navigation for Accurate, Real-time Catheter Positioning and Ablation in Cardiac Electrophysiology Procedures
Published on: April 21, 2013
09:17High-Resolution Endocardial and Epicardial Optical Mapping in a Sheep Model of Stretch-Induced Atrial Fibrillation
Published on: July 29, 2011
Related Concept Videos
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation
Electrocardiogram Fundamentals
An electrocardiogram (ECG) is a diagnostic tool for identifying cardiac conditions such as arrhythmias, conduction abnormalities, and myocardial ischemia.
Definition
An electrocardiogram (ECG) visualizes the heart's electrical activity by tracing the electrical movement associated with each heartbeat on a graph or monitor. As the heart beats, an electrical wave passes through it, correlating with the cardiac cycle events.
Parts of an ECG
An ECG utilizes electrodes on the skin...