Related Experiment Video
Updated: Jul 25, 2025

Determination of the Mechanical Properties of Flexible Connectors for Use in Insulated Concrete Wall Panels
Published on: October 19, 2022
Development and Promotion of Concrete Strength at Initial 24 Hours
Chuanhe Fan1, Jueshi Qian1, Huaqiang Sun2
1College of Materials Science and Engineering, Chongqing University, Chongqing 400044, China.
Abstract:
Knowing and promoting the strength development of concrete at an earlier age is essential for accelerating formwork circulation of the on-site construction and precast product manufacture. The strength development rate at earlier ages of less than the initial 24 h was investigated. The effect of measures of adding silica fume, calcium sulfoaluminate cement, and early strength agent on the strength development of earlier concrete at ambient temperatures of 10, 15, 20, 25, and 30 °C was studied. The microstructure and long-term properties were further tested. It is shown that the strength increases exponentially first and then logarithmically, different from what is commonly recognized. Increasing cement content exhibited a certain effect only above 25 °C. When the cement content increased from 420 to 460 kg/m3, the strength only increased from 6.2 to 6.7 MPa after 12 h at 25 °C. The early strength agent could increase the strength significantly, the strength could be increased from 6.4 to 10.8 MPa after 20 h at 10 °C and from 7.2 to 20.6 MPa after 14 h at 20 °C. All measures for promoting earlier strength did not have an evident negative effect. The results could be potentially referred for the formwork removal at a suitable moment.
More Related Videos
11:07Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
10:00Experimental Protocol to Determine the Chloride Threshold Value for Corrosion in Samples Taken from Reinforced Concrete Structures
Published on: August 31, 2017
Related Concept Videos
Strength and Heat of Hydration
The heat of hydration for each cement compound is significant; for instance, tricalcium aluminate (C3A) and...
Fatigue Strength of Concrete
Testing Water Quality
Impact Strength of Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Bonding and Strength of Aggregate