Preparation of Aligned Steel Fiber Reinforced Cementitious Composite and Its Flexural Behavior
Published on: June 27, 2018
Experimental Study on Compressive and Flexural Performance of Lightweight Cement-Based Composites Reinforced with
Cong-Thuat Dang1, My Pham1, Ngoc-Hieu Dinh1
1Faculty of Civil Engineering, The University of Danang-University of Science and Technology, 54 Nguyen Luong Bang, Danang 550000, Vietnam.
Abstract:
This paper aims to experimentally study the compressive and flexural characteristics of cement-based composites developed for fabricating thin, lightweight, and high-performance components of buildings. Expanded hollow glass particles with a 0.25-0.5 mm particle size were used as lightweight fillers. Hybrid fibers made of amorphous metallic (AM) and nylon fibers were used to reinforce the matrix with a total volume fraction of 1.5%. The primary test parameters included the expanded glass-to-binder (EG/B) ratio, the fiber volume content ratio, and the length of the nylon fibers in the hybrid system. The experimental results demonstrate that the EG/B ratio and the volume dosage of the nylon fibers exhibited insignificant effects on the compressive strength of the composites. Additionally, the utilization of nylon fibers with a longer length of 12 mm resulted in a slight compressive strength reduction of approximately 13% compared to that of the 6 mm nylon fibers. Further, the EG/G ratio exhibited an insignificant effect on the flexural behavior of lightweight cement-based composites in terms of their initial stiffness, strength, and ductility. Meanwhile, the increasing AM fiber volume fraction in the hybrid system from 0.25% to 0.5% and 1.0% improved flexural toughness by 42.8% and 57.2%, respectively. In addition, the nylon fiber length significantly affected the deformation capacity at the peak load and the residual strength in the post-peak stage.
Related Concept Videos
Fiber Reinforced Concrete
Strength of Cement
For compressive strength tests, ASTM C 109-05 standards prescribe a cement-sand mix ratio of 1:2.75 and a water/cement ratio of 0.485 for making 2-inch cubes. These cubes are mixed, cast, and cured in saturated lime water at 23°C until testing. Flexural strength testing, outlined in...
Behavior of Concrete Under Compressive Load
As the concrete specimen fractures under...
Tensile Strength Considerations of Concrete
The dimensions and shape of a concrete specimen...
Relation Between Tensile Strength and Compressive Strength of Concrete
Impact Strength of Concrete