Objective:
Myocardial extracellular volume (ECV) fraction is an important imaging biomarker in clinical decision-making. CT-ECV is a potential alternative to MRI for ECV quantification. We conducted a meta-analysis to comprehensively assess the reliability of CT for ECV quantification with MRI as a reference.
Methods:
We systematically searched PubMed, EMBASE, and the Cochrane Library for relevant articles published since the establishment of the database in July 2022. The articles comparing CT-ECV with MRI as a reference were included. Meta-analytic methods were applied to determine the pooled weighted bias, limits of agreement (LOA), and correlation coefficient (r) between CT-ECV and MRI-ECV.
Results:
Seventeen studies with a total of 459 patients and 2231 myocardial segments were included. The pooled mean difference (MD), LOA, and r for ECV quantification at the per-patient level was (0.07%; 95% LOA: - 0.42 to 0.55%) and 0.89 (95% CI: 0.86-0.91), respectively, while on the per-segment level was (0.44%; 95% LOA: 0.16-0.72%) and 0.84 (95% CI: 0.82-0.85), respectively. The pooled r from studies with the ECViodine method for ECV quantification was significantly higher compared to those with the ECVsub method (0.94 (95% CI: 0.91-0.96) vs. 0.84 (95% CI: 0.80-0.88), respectively, p = 0.03). The pooled r from septal segments was significantly higher than those from non-septal segments (0.88 (95% CI: 0.86-0.90) vs. 0.76 (95% CI: 0.71-0.90), respectively, p = 0.009).
Conclusion:
CT showed a good agreement and excellent correlation with MRI for ECV quantification and is a potentially attractive alternative to MRI.
Clinical Relevance Statement:
The myocardial extracellular volume fraction can be acquired using a CT scan, which is not only a viable alternative to myocardial extracellular volume fraction derived from MRI but is also less time-consuming and costly for patients.
Key Points:
• Noninvasive CT-ECV is a viable alternative to MRI-ECV for ECV quantification. • CT-ECV using the ECViodine method showed more accurate myocardial ECV quantification than ECVsub. • Septal myocardial segments showed lower measurement variability than non-septal segments for the ECV quantification.
More Related Videos
08:05Cardiac Response to β-Adrenergic Stimulation Determined by Pressure-Volume Loop Analysis
Published on: May 19, 2021
11:13Quantification of Mouse Heart Left Ventricular Function, Myocardial Strain, and Hemodynamic Forces by Cardiovascular Magnetic Resonance Imaging
Published on: May 24, 2021
Related Concept Videos
Imaging Studies for Cardiovascular System V: CT
Imaging Studies for Cardiovascular System IV: CMRI
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for...