Related Experiment Video
Updated: Jul 25, 2025

Automated 90Sr Separation and Preconcentration in a Lab-on-Valve System at Ppq Level
Published on: June 6, 2018
Detection Capability of 89Sr and 90Sr Using Liquid Scintillation Counting
Ezekiel Blain1, Kimi Nishikawa1, Sherry A Faye
1Wadsworth Center, New York State Department of Health, Albany, NY 12201.
Abstract:
We developed a new method for simultaneous determination of 89Sr and 90Sr with an emphasis on detectability. The samples were digested, and Sr was chemically purified followed by a single count on a liquid scintillation counter in three windows overlapping the 90Sr, 89Sr, and 90Y peaks. Gamma spectrometry was used to measure 85Sr, added for chemical recovery. The method was tested on 18 water samples spiked at levels from 9 to 242 Bq of 89Sr and 90Sr, with either single radionuclides or their mixtures. In addition, eight method blanks were measured. The data were analyzed numerically by solving a system of linear equations for 89Sr and 90Sr activities as analytes and 90Y activity as a participating component. The total uncertainties of the results were calculated numerically using variances and covariances. The average bias from the known activities was -0.3% (range from -3.6 to 3.1%) for 90Sr and - 1.5% (range from -10.1 to 5.1%) for 89Sr. The En-scores were within -1.0 and 1.0 at 95% confidence level. The detection capabilities of this method were determined by means of the decision threshold LC and the limit of detection referred to as the minimum detectable activity. All relevant uncertainties were propagated into the LC and minimum detectable activity. In addition, detection limits were calculated for the purpose of Safe Drinking Water Act monitoring. The detection capabilities were compared with the regulatory requirements in the US and EU for food and water. For samples spiked with either pure 89Sr or 90Sr, false positives were observed for the opposite radionuclide exceeding the above LC values. This was attributed to interference by the spiked activity. A new method was developed to calculate decision and detectability curves in the presence of interference.
More Related Videos
06:28Visualization of Low-Level Gamma Radiation Sources Using a Low-Cost, High-Sensitivity, Omnidirectional Compton Camera
Published on: January 30, 2020
07:52A Novel Technique for Raman Analysis of Highly Radioactive Samples Using Any Standard Micro-Raman Spectrometer
Published on: April 12, 2017
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
High-Performance Liquid Chromatography: Types of Detectors
Atomic Emission Spectroscopy: Lab
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Gas Chromatography: Types of Detectors-II
Atomic Absorption Spectroscopy: Instrumentation
The atomizer used in AAS can be either a flame atomizer or an...