Related Experiment Video
Updated: Jul 25, 2025

A Probing Device for Quantitatively Measuring the Mechanical Properties of Soft Tissues during Arthroscopy
Published on: May 1, 2020
Arthroscopic Visualization Is a Reliable Method of Confirming Femoral Button Placement During Anterior Cruciate
Michael J Talamo1, Julio Ojea Quintana1, Clifford Voigt1
1ONS Foundation for Clinical Research and Education, Greenwich, Connecticut, U.S.A.
Purpose:
To compare arthroscopic visualization with intraoperative fluoroscopy for confirming proper femoral button placement during ACLR.
Methods:
Fifty consecutive patients undergoing soft-tissue ACLR between March 2021 and February 2022 were evaluated for inclusion in this study. Both primary and revision ACLR cases using suspensory fixation were included. Surgeons rated their confidence of proper button placement from both an intra-articular perspective (through the femoral tunnel) and an extra-articular perspective (through the iliotibial band) by grading confidence with a Likert scale. Fluoroscopy was also performed for confirmation of proper button placement.
Results:
Fifty consecutive patients (35.1 ± 14.5 years of age) with soft-tissue ACLR were included. Mean surgeon Likert confidence scores for accurate button placement were as follows: 4.1 of 5 ± 0.9 from an intra-articular perspective, 4.6 of 5 ± 0.7 from an extra-articular perspective, and 8.7 of 10 ± 1.4 based on the sum of intra- and extra-articular perspectives. Fluoroscopic findings demonstrated that 48 of 50 cases had an appropriate flipped button on the lateral cortex of the femur. I total, 2 of 50 had soft-tissue interposition. Cases in which surgeons had high confidence from both intra- and extra-articular perspectives (≥9/10 sum score) were indicative of proper button placement 97% of the time.
Conclusions:
Arthroscopic visualization is a reliable method of confirming femoral button placement during ACLR and is sufficient to rule out intraoperative fluoroscopy during surgery. ACLR cases with high surgeon confidence from both intra- and extra-articular perspectives (sum score of 9 or greater out of 10) resulted in proper femoral button placement in 97% of cases as confirmed by intraoperative fluoroscopy.
Level Of Evidence:
Level II, prospective cohort study.
More Related Videos
04:42Treatment with Locking Intramedullary Nailing for Intertrochanteric Fracture of the Femur Utilizing a New Awl with a Distal Positioner
Published on: June 6, 2025
06:27Author Spotlight: Investigating Early Events and Long-Term Effects of ACL Injuries for Osteoarthritis Progression
Published on: September 29, 2023