Measuring the Pseudocapacitive Behavior of Individual V2O5 Particles by Scanning Electrochemical Cell Microscopy

Cong Gao1, Yingjian Li1, Jiao Zhao1

  • 1State Key Laboratory for Modification of Chemical Fibers and Polymer Materials, College of Chemistry and Chemical Engineering, Donghua University, Shanghai 201620, China.

PubMed

Related Concept Videos

Interfacial Electrochemical Methods: Overview01:06

Interfacial Electrochemical Methods: Overview

Interfacial electrochemical methods focus on the phenomena occurring at the boundary between an electrode and a solution, as opposed to bulk methods that concentrate on the solution's overall properties. These interfacial methods are classified as either static or dynamic based on the presence of a nonzero current in the electrochemical cell and the consistency of analyte concentrations. Static methods, such as potentiometry, measure the cell's potential without any significant current...
289
Controlled-Potential Coulometry: Electrolytic Methods01:17

Controlled-Potential Coulometry: Electrolytic Methods

Controlled-potential coulometry, also known as potentiostatic coulometry, employs a three-electrode system in which the working electrode's potential is precisely regulated using a potentiostat. Platinum working electrodes are utilized for positive potentials, while mercury pool electrodes are favored for extremely negative potentials. The platinum counter electrode is separated from the analyte using a membrane or salt bridge to avoid interference in the analysis.
The chosen potential...
216
Voltammetric Techniques: Linear-Scan (E vs Time)01:12

Voltammetric Techniques: Linear-Scan (E vs Time)

Polarography is a classical voltammetric technique used to analyze electrochemical reactions. This method applies a linear potential sweep to a dropping mercury electrode (DME), and the resulting current is measured. A dropping mercury electrode is commonly used as the working electrode in polarography. It consists of a capillary tube filled with mercury, where the tiny droplet forms at the tip. This droplet continuously drops from the capillary, creating a new electrode surface for each...
437
Atomic Force Microscopy01:08

Atomic Force Microscopy

Atomic force microscopy (AFM) is a type of scanning probe microscopy that can analyze topographic details of various specimens like ceramics, glass, polymers, and biological samples. AFM offers over 1000 times more resolution than the optical imaging system. Images generated from AFM are three-dimensional surface profiles, offering an advantage over the flat, two-dimensional images from other imaging techniques.
The AFM Probe
The probe is regarded as the heart of any AFM setup and comprises the...
3.5K
Scanning Electron Microscopy01:07

Scanning Electron Microscopy

A scanning electron microscope (SEM) is used to study the surface features of a sample by using an electron beam that scans the sample surface in a two-dimensional manner. Typically, areas between ~1 centimeter to 5 micrometers in width can be imaged. SEM can be used to image bacteria, viruses, tissues as well as larger samples like insects. Conventional SEM gives a magnification ranging from 20X to 30,000X and spatial resolution of 50 to 100 nanometers.
Fundamental Principles
Accelerated...
4.3K
Voltammetric Techniques: Cyclic Voltammetry01:10

Voltammetric Techniques: Cyclic Voltammetry

Cyclic voltammetry (CV) is an electrochemical technique used to investigate the redox properties of a chemical species. It involves measuring the current response of an electrochemical cell as a function of the applied potential. The setup for cyclic voltammetry typically consists of a working electrode, a reference electrode, and a counter electrode—all immersed in an electrolyte solution. The working electrode is where the redox reaction of interest occurs, while the reference electrode...
558