Related Experiment Video
Updated: Jul 24, 2025

Using Capillary Electrophoresis to Quantify Organic Acids from Plant Tissue: A Test Case Examining Coffea arabica Seeds
Published on: November 12, 2016
SHS-GC-MS applied in Coffea arabica and Coffea canephora blend assessment
Marcos Valério Vieira Lyrio1, Pedro Henrique Pereira da Cunha1, Danieli Grancieri Debona1
1Federal University of Espírito Santo (UFES), Department of Chemistry, Campus Goiabeiras, Avenida Fernando Ferrari, 514, CEP 29075-910 Vitoria, Espírito Santo, Brazil. filgueiras.pr@gmail.com.
Abstract:
Considering the great economic significance of Coffea arabica (arabica) associated with the lower production cost of C. canephora (conilon), blends of these coffees are commercially available to reduce costs and combine sensory attributes. Thus, analytical tools are required to ensure consistency between real and labeled compositions. In this sense, chromatographic methods based on volatile analysis using static headspace-gas chromatography-mass spectrometry (SHS-GC-MS) and Fourier transform infrared (FTIR) spectroscopy associated with chemometric tools were proposed for the identification and quantification of arabica and conilon blends. The peak integration from the total ion chromatogram (TIC) and extracted ion chromatogram (EIC) was compared in multivariate and univariate scenarios. The optimized partial least squares (PLS) models with uninformative variable elimination (UVE) and chromatographic data (TIC and EIC) have similar accuracy according to a randomized test, with prediction errors between 3.3% and 4.7% and Rp2 > 0.98. There was no difference between the univariate models for the TIC and EIC, but the FTIR model presented a lower performance than GC-MS. The multivariate and univariate models based on chromatographic data had similar accuracy. For the classification models, the FTIR, TIC, and EIC data presented accuracies from 96% to 100% and error rates from 0% to 5%. Multivariate and univariate analyses combined with chromatographic and spectroscopic data allow the investigation of coffee blends.
More Related Videos
08:43PTR-ToF-MS Coupled with an Automated Sampling System and Tailored Data Analysis for Food Studies: Bioprocess Monitoring, Screening and Nose-space Analysis
Published on: May 11, 2017
09:11Caffeine Extraction, Enzymatic Activity and Gene Expression of Caffeine Synthase from Plant Cell Suspensions
Published on: October 2, 2018
Related Concept Videos
2D NMR: Heteronuclear Single-Quantum Correlation Spectroscopy (HSQC)
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
High-Resolution Mass Spectrometry (HRMS)