Related Experiment Video
Updated: Jul 24, 2025

Visualizing Uniaxial-strain Manipulation of Antiferromagnetic Domains in Fe1+YTe Using a Spin-polarized Scanning Tunneling Microscope
Published on: March 24, 2019
Tunable interplay between exchange coupling and uniaxial magnetic anisotropy in epitaxial CoO/Au/Fe trilayers
H Nayyef1, E Świerkosz1, W Janus1
1Faculty of Physics and Applied Computer Science, AGH University of Krakow, Kraków, Poland.
Abstract:
We show that the interaction between ferromagnetic Fe(110) and antiferromagnetic CoO(111) sublayers can be mediated and precisely tuned by a nonmagnetic Au spacer. Our results prove that the thickness of the Fe and Au layers can be chosen to modify the effective anisotropy of the Fe layer and the strength of the exchange bias interaction between Fe and CoO sublayers. Well-defined and tailorable magnetic anisotropy of the ferromagnet above Néel temperature of the antiferromagnet is a determining factor that governs exchange bias and interfacial CoO spins orientation at low temperatures. In particular, depending on the room temperature magnetic state of Fe, the low-temperature exchange bias in a zero-field cooled system can be turned "off" or "on". The other way around, we show that exchange bias can be the dominating magnetic anisotropy source for the ferromagnet and it is feasible to induce a 90-degree rotation of the easy axis as compared to the initial, exchange bias-free easy axis orientation.
Related Concept Videos
Ferromagnetism
Spin–Spin Coupling: One-Bond Coupling
Colors and Magnetism
When atoms or molecules absorb light at the proper frequency, their electrons are excited to higher-energy orbitals. For many main group atoms and molecules, the absorbed photons are in the ultraviolet range of the electromagnetic spectrum, which cannot be detected by the human eye. For coordination compounds, the energy difference between the d orbitals often allows photons in the visible range to be absorbed and emitted, which is seen as colors by the human...
Spin–Spin Coupling: Two-Bond Coupling (Geminal Coupling)
The central atom need not be NMR-active because its electrons are affected by the electron polarization of the spin-active atoms. However, spin information is transmitted less effectively than in one-bond coupling, and 2J values are usually weaker than 1J values. The energy of...
Spin–Spin Coupling: Three-Bond Coupling (Vicinal Coupling)
The extent of coupling depends on the C‑C bond length, the two H‑C‑C angles, any electron-withdrawing substituents, and the dihedral angle between the...
NMR Spectroscopy: Spin–Spin Coupling

