Related Experiment Video
Updated: Aug 6, 2026

Measurement and Analysis of Extracellular Acid Production to Determine Glycolytic Rate
Published on: December 12, 2015
Photometric flow system for the determination of serum lactate dehydrogenase activity
Justyna Głowacka1, Agnieszka Wiśniewska2, Robert Koncki1
1University of Warsaw, Faculty of Chemistry, Pasteura 1, 02-093, Warsaw, Poland.
Abstract:
The routine method for LDH (Lactate dehydrogenase) activity determination is to monitor the increase of NADH concentration at 340 nm. There are some inconvenience in taking measurements in the near-UV region, especially in the case of serum samples analysis. In this work, two modifications of the routine LDH activity assay based on the use of reducing properties of NADH have been compared. Both methods involved the reduction of compounds that can be easily determined by well-known methods, ferric ion (with ferrozine) and nitrotetrazolium blue (NBT). A fully-mechanized Multicommutated Flow Analysis-Paired Emitter Detector Diode (MCFA-PEDD) system based on solenoid devices was developed and applied for both methods. The linear ranges obtained for Fe-ferrozine and NBT methods are 6.0-200.0 U L-1 and 10.0-250.0 U L-1 with estimated detection limits at 0.2 U L-1 and 4.5 U L-1, respectively. The low LOQ values enabled 10-fold sample dilutions, which is advantageous for samples with limited available volume. The Fe-ferrozine method is more selective for LDH activity in the presence of glucose, ascorbic acid, albumin, bilirubin, copper and calcium ions than NBT method. To confirm the analytical usefulness of the proposed flow system, the analysis of real human serum samples was carried out. The statistic tests showed satisfactory correlation between the results obtained for both developed methods and those received using the reference method.
More Related Videos
06:18Mapping Metabolism: Monitoring Lactate Dehydrogenase Activity Directly in Tissue
Published on: June 21, 2018
09:34The Lactate Dehydrogenase Sequestration Assay — A Simple and Reliable Method to Determine Bulk Autophagic Sequestration Activity in Mammalian Cells
Published on: July 27, 2018
Related Concept Videos
UV–Vis Spectrometers
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.