Load-Bearing Performance of Non-Prismatic RC Beams Wrapped with Carbon FRP Composites
Suniti Suparp1, Ali Ejaz2, Kaffayatullah Khan3
1Department of Civil and Environmental Engineering, Faculty of Engineering, Srinakharinwirot University, Nakhonnayok 26120, Thailand.
Abstract:
This study investigated the influence of CFRP composite wrapping techniques on the load-deflection and strain relationships of non-prismatic RC beams. A total of twelve non-prismatic beams with and without openings were tested in the present study. The length of the non-prismatic section was also varied to assess the effect on the behavior and load capacity of non-prismatic beams. The strengthening of beams was performed by using carbon fiber-reinforced polymer (CFRP) composites in the form of individual strips or full wraps. The linear variable differential transducers and strain gauges were installed at the steel bars to observe the load-deflection and strain responses of non-prismatic RC beams, respectively. The cracking behavior of unstrengthened beams was accompanied by excessive flexural and shear cracks. The influence of CFRP strips and full wraps was primarily observed in solid section beams without shear cracks, resulting in enhanced performance. In contrast, hollow section strengthened beams exhibited minor shear cracks alongside the primary flexural cracks within the constant moment region. The absence of shear cracks was reflected in the load-deflection curves of strengthened beams, which demonstrated a ductile behavior. The strengthened beams demonstrated 40% to 70% higher peak loads than control beams, whereas the ultimate deflection was increased up to 524.87% compared to that of the control beams. The improvement in the peak load was more prominent as the length of the non-prismatic section increased. A better improvement in ductility was achieved for the case of CFRP strips in the case of short non-prismatic lengths, whereas the efficiency of CFRP strips was reduced as the length of the non-prismatic section increased. Moreover, the load-strain capacity of CFRP-strengthened non-prismatic RC beams was higher than the control beams.
Related Concept Videos
Design of Prismatic Beams for Bending
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...
Beams with Unsymmetric Loadings
The first moment-area theorem determines the slope at any point on the beam. This theorem indicates that the change in slope between two points on a beam...
Fiber Reinforced Concrete
Beams with Symmetric Loadings
The M/EI...
Impact Loading on a Cantilever Beam
When an object is dropped onto the free end of a cantilever, its potential energy due to gravity is...