Related Experiment Video
Updated: Jul 24, 2025

Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
Cross-Check QA: A Quality Assurance Workflow to Prevent Missed Diagnoses by Alerting Inadvertent Discordance Between
Mariam Chekmeyan1, Steven J Baccei2, Elisabeth R Garwood3
1UMass Chan Medical School, Worcester, Massachusetts.
Purpose:
The aim of this study was to implement and evaluate a quality assurance (QA) workflow that leverages natural language processing to rapidly resolve inadvertent discordance between radiologists and an artificial intelligence (AI) decision support system (DSS) in the interpretation of high-acuity CT studies when the radiologist does not engage with AI DSS output.
Methods:
All consecutive high-acuity adult CT examinations performed in a health system between March 1, 2020, and September 20, 2022, were interpreted alongside an AI DSS (Aidoc) for intracranial hemorrhage, cervical spine fracture, and pulmonary embolus. CT studies were flagged for this QA workflow if they met three criteria: (1) negative results by radiologist report, (2) a high probability of positive results by the AI DSS, and (3) unviewed AI DSS output. In these cases, an automated e-mail notification was sent to our quality team. If discordance was confirmed on secondary review-an initially missed diagnosis-addendum and communication documentation was performed.
Results:
Of 111,674 high-acuity CT examinations interpreted alongside the AI DSS over this 2.5-year time period, the frequency of missed diagnoses (intracranial hemorrhage, pulmonary embolus, and cervical spine fracture) uncovered by this workflow was 0.02% (n = 26). Of 12,412 CT studies prioritized as depicting positive findings by the AI DSS, 0.4% (n = 46) were discordant, unengaged, and flagged for QA. Among these discordant cases, 57% (26 of 46) were determined to be true positives. Addendum and communication documentation was performed within 24 hours of the initial report signing in 85% of these cases.
Conclusions:
Inadvertent discordance between radiologists and the AI DSS occurred in a small number of cases. This QA workflow leveraged natural language processing to rapidly detect, notify, and resolve these discrepancies and prevent potential missed diagnoses.
More Related Videos
Related Concept Videos
Radiological Investigation I: X-ray and CT
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT