Lauren Butler1, Charles Wyatt2,3, Alexa Martinez1
1Nicklaus Children's Hospital.
Background And Purpose:
The Expanded Cutting Alignment Scoring Tool (E-CAST) is a two-dimensional qualitative scoring system that has demonstrated moderate inter-rater and good intra-rater reliability for the assessment of trunk and lower extremity alignment during a 45-degree sidestep cut. The primary purpose of this study was to examine the reliability of the quantitative version of the E-CAST among physical therapists and to compare the reliability of the quantitative E-CAST to the original qualitative E-CAST. The hypothesis was that the quantitative version of the E-CAST would demonstrate greater inter-rater and intra-rater reliability compared to the qualitative E-CAST.
Study Design:
Observational cohort, repeated measures reliability study.
Methods:
Twenty-five healthy female athletes (age 13.8±1.4 years) performed three sidestep cuts with two-dimensional video capturing frontal and sagittal views. Two physical therapist raters independently scored a single trial using both views on two separate occasions. Based on the E-CAST criteria, select kinematic measurements were extracted using a motion analysis phone application. Intraclass correlation coefficients and 95% confident intervals were calculated for the total score, and kappa coefficients were calculated per kinematic variable. Correlations were converted to z-scores and compared to the six original criteria for significance (α<0.05).
Results:
Cumulative intra- and inter-rater reliability were both good (ICC=0.821, 95% CI 0.687-0.898 and ICC=0.752, 95% CI 0.565-0.859). Cumulative intra-rater kappa coefficients ranged from moderate to almost perfect, and cumulative inter-rater kappa coefficients ranged from slight to good. No significant differences were observed between the quantitative and qualitative criteria for either inter- or intra-rater reliability (Zobs(intra)= -0.38, p=0.352 and Zobs(inter)= -0.30, p=0.382).
Conclusion:
The quantitative E-CAST is a reliable tool to assess trunk and lower extremity alignment during a 45-degree sidestep cut. No significant differences were observed in reliability of the quantitative versus qualitative assessment.
Level Of Evidence:
3b.
Related Concept Videos
Kinematic Equations: Problem Solving
Relative Motion Analysis - Acceleration
Relative Motion Analysis using Rotating Axes-Problem Solving
Here, in order to determine the magnitude of velocity and acceleration for point...
Relative Motion Analysis using Rotating Axes
However, to express the relative position of point B relative to point A, an additional frame of reference, denoted as x'y', is necessary. This additional frame not only translates but also rotates relative to the fixed frame, making it...
Kinematic Equations - II
Suppose a car merges into freeway traffic on a 200 m long ramp. If its initial velocity is 10 m/s and it accelerates at 2 m/s2, then the...
Absolute Motion Analysis- General Plane Motion
As the drone's propellers rotate, an upward force is generated that counteracts the force of gravity, enabling the drone to lift off from the ground. This initial movement of the drone is along a straight path, representing a form of translational motion. In this phase, every point on the...