Identification of Abnormal Data for Synchronous Monitoring of Transformer DC Bias Based on Multiple Criteria
Zhongqing Kou1, Sheng Lin1, Aimin Wang2
1School of Electrical Engineering, Southwest Jiaotong University, Chengdu 611756, China.
Abstract:
Seriously abnormal data exist in the synchronous monitoring data of transformer DC bias, which causes serious data feature contamination and even affects the identification of transformer DC bias. For this reason, this paper aims to ensure the reliability and validity of synchronous monitoring data. This paper proposes an identification of abnormal data for the synchronous monitoring of transformer DC bias based on multiple criteria. By analyzing the abnormal data of different types, the characteristics of abnormal data are obtained. Based on this, the abnormal data identification indexes are introduced, including gradient, sliding kurtosis and Pearson correlation coefficient. Firstly, the Pauta criterion is used to determine the threshold of the gradient index. Then, gradient is used to identify the suspected abnormal data. Finally, the sliding kurtosis and Pearson correlation coefficient are used to identify the abnormal data. Data for synchronous monitoring of transformer DC bias in a certain power grid are used to verify the proposed method. The results show that the accuracy of the proposed method in identifying mutated abnormal data and zero-value abnormal data is claimed to be 100%. Compared with traditional abnormal data identification methods, the accuracy of the proposed method is significantly improved.
More Related Videos
06:45Design and Application of a Fault Detection Method Based on Adaptive Filters and Rotational Speed Estimation for an Electro-Hydrostatic Actuator
Published on: October 28, 2022
08:25Combined Invasive Subcortical and Non-invasive Surface Neurophysiological Recordings for the Assessment of Cognitive and Emotional Functions in Humans
Published on: May 19, 2016
Related Concept Videos
Differential Relays
Three-Phase Short Circuit—Unloaded Synchronous Machine
This behavior occurs due to the magnetic flux produced by the short-circuit armature currents. Initially, these currents follow high-reluctance paths but eventually shift to...
Instrument Transformers
Directional Relays
Power System Three-Phase Short Circuits
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...