Related Experiment Video
Updated: Jul 23, 2025

Flexible Colonoscopy in Mice to Evaluate the Severity of Colitis and Colorectal Tumors Using a Validated Endoscopic Scoring System
Published on: October 16, 2013
Long-Term Follow-Up of Colonoscopy Quality Monitoring
Feenalie Patel1, Christen Dilly1,2, Nabil Fayad1,2
1Department of Medicine, Division of Gastroenterology and Hepatology, Indianapolis, Indiana, USA.
Introduction:
High-quality colonoscopy is paramount for colorectal cancer prevention. Since 2009, endoscopists at our institution have received quarterly report cards summarizing individual colonoscopy quality indicators. We have previously shown that implementing this intervention was associated with short-term improvement in adenoma detection rate (ADR). However, the long-term effect of continued monitoring on colonoscopy quality is unclear.
Methods:
We conducted a retrospective study of prospectively administered quarterly colonoscopy quality report cards at the Roudebush Veteran's Affairs Medical Center between April 1, 2012, and August 31, 2019. The anonymized reports included individual endoscopists' ADRs, cecal intubation rates, and withdrawal times. Analyses were performed to determine slopes over time for each quality metric by physician and assess for differences based on whether ADRs were calculated quarterly or yearly.
Results:
Data from the report cards of 17 endoscopists who had performed 24,361 colonoscopies were included. The mean quarterly ADR (±SD) was 51.7% (±11.7%) and mean yearly ADR was 47.2% (±13.8%). There was a small increase in overall ADR based on quarterly and yearly measurements (slope + 0.6%, P = 0.02; and slope +2.7%, P < 0.001, respectively), but no significant change in individual ADRs, cecal intubation rates, or withdrawal times. Analysis of SD of ADRs showed no significant difference between yearly and quarterly measurements ( P = 0.064). Individual endoscopists' ADR SD differences between yearly and quarterly measurements ranged from -4.7% to +6.8%.
Discussion:
Long-term colonoscopy quality monitoring paralleled stable improvements in overall ADR. For endoscopists with baseline high ADR, frequent monitoring and reporting of colonoscopy quality metrics may not be necessary.
More Related Videos
03:44Structured Approach to Colonoscopy Technique Optimization: A Single-Center Experience with Novice Endoscopists
Published on: July 11, 2025
06:28E-Patient Counseling Trial E-PACO: Computer Based Education versus Nurse Counseling for Patients to Prepare for Colonoscopy
Published on: August 1, 2019
Related Concept Videos
Endoscopic Procedures II: Colonoscopy
Imaging Studies III: Gastrointestinal Motility Studies and Virtual Colonoscopy
Radionuclide Testing
Radionuclide testing is a sophisticated medical technique for assessing gastrointestinal motility. It focuses on gastric emptying and colonic transit time. Radioactive markers track the movement of food through the digestive system, providing insights into gastrointestinal disorders.
In gastric emptying studies, a meal's liquid and...
Endoscopic Procedures IV: Sigmoidoscopy and Laproscopy
Sigmoidoscopy
Sigmoidoscopy is a diagnostic procedure that uses a flexible sigmoidoscope equipped with a light source and camera to examine the rectum and sigmoid colon. The procedure involves inserting the tube through the anus...
Endoscopic Procedures III: Video Capsule Endoscopy
Endoscopic Procedures I: Esophagogastroduodenoscopy
During an EGD, the endoscope can be used to:
Lower GI Series: Barium Enema
Procedure Details
The examination begins by inserting a lubricated rectal tube into the patient's rectum to administer a radiopaque barium solution. The barium flow is carefully...