In breast reconstruction, mastectomy and free flaps are susceptible to vascular compromise and tissue necrosis. The SnapshotNIR device (Kent Imaging, Calgary, AB, Canada) utilizes near-infrared spectroscopy to measure tissue oxygen saturation (StO2) and hemoglobin concentration. Here, we report on the use of this device for StO2 monitoring among patients receiving alloplastic or autologous breast reconstruction.
Methods:
Patients receiving immediate alloplastic reconstruction after mastectomy or autologous reconstruction were enrolled. Preoperative, intraoperative, and postoperative images were taken of the flaps. StO2 and hemoglobin were measured at the following locations: superior and inferior breast, free flap skin paddle (when applicable), and un-operated control skin. Linear mixed effects model for repeated measurements was used to model measurements to estimate the area effect difference across time, time effect difference across area, and pairwise comparisons between two areas at each time point.
Results:
Thirty-two breasts underwent alloplastic reconstruction; 38 breasts underwent autologous reconstruction. No enrollees developed skin necrosis. StO2 was highest after mastectomy and closure in alloplastic reconstructions. StO2 was observed to decline at follow-up in autologous reconstructions. Mean preoperative StO2 was highest in breasts that had previously undergone mastectomy and alloplastic reconstruction.
Conclusions:
The SnapshotNIR device detected normal spatial and temporal differences in tissue oxygenation over the operative course of alloplastic and autologous breast reconstruction. A multi-institutional, prospective clinical trial is needed to determine the sensitivity and specificity of this device for detecting skin flap necrosis.
More Related Videos
14:28Non-Invasive Monitoring of Microvascular Oxygenation and Reactive Hyperemia using Hybrid, Near-Infrared Diffuse Optical Spectroscopy for Critical Care
Published on: May 10, 2024
07:28Donor Posterior Atrial Flap Rotation for Left Atrial Cuff Reconstruction in Lung Transplantation
Published on: October 11, 2024
Related Concept Videos
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...