Modified calibration protocols in electron beam dosimetry: comparison with IAEA TRS-398 and AAPM TG-51
Cica Yulinar1,2, Muhamad Iqbal Assegab3, Wahyu Edy Wibowo3
1Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok, Indonesia.
Abstract:
This study aimed to compare absolute calibration outputs based on the protocols of the International Atomic Energy Agency (IAEA) Technical Report Series (TRS)-398, the American Association of Physicists in Medicine (AAPM) Task Group (TG)-51, and modified calibration approach. The electron beam output calibration followed the IAEA TRS-398 and AAPM TG-51 protocols, both of which required cylindrical chambers and parallel plates. However, the use of cylindrical chambers is not recommended at low energies because of the large fluence-correction factor. TG-51 recommended cross-calibration of the parallel-plate chamber against the cylindrical chamber in a high-energy electron beam. In 2020, an electron beam dosimetry modification was introduced that used a cylindrical ionisation chamber at all energies and updated the data for beam quality conversion factors. This modification provided a lower deviation than that reported in AAPM TG-51. Thus, the modified calibration based on TRS-398 was applied in the present study, which yielded results below the permissible tolerance. The beam calibration at 6, 8, 10, 12, and 15 MeV energies was carried out for two Elekta linear accelerators.. Electron beam dosimetry followed the AAPM TG-51 and TRS-398 protocols, and modified calibration were performed to measure the dose at the maximum depth expressed in dose/monitor units (cGy/MU). Charge-reading measurements were measured using ionisation chambers PTW 30013, IBA CC13, and Exradin A11. The average absorbed dose ratios were 1.004 and 1.009 using the modified calibration and TRS-398 and modified calibration and TG-51, respectively. Therefore, based on IAEA TRS-398, the results were below the tolerance limit (±2%).
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
10:33Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification ADCI and Dose Estimation
Published on: September 4, 2017
Related Concept Videos
Atomic Absorption Spectroscopy: Lab
Solutions containing organic solvents, such as low-molecular-mass alcohols, esters, or ketones, enhance absorbances by increasing...
Atomic Emission Spectroscopy: Lab
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Atomic Emission Spectroscopy: Overview
Biological Effects of Radiation