Analysis of dose distribution reproducibility based on a fluence map of in vivo transit dose using an electronic
Didin Tardi1, Aninda Fitriandini2, Annisa Rahma Fauziah2
1Department of Physics, Faculty of Mathematics and Natural Sciences, Universitas Indonesia, Depok, West Java, 16424, Indonesia.
Abstract:
Morphological changes can affect distribution of dose in patients. Determination of the dose distribution changes for each fraction radiotherapy can be done by relativein vivodosimetry (IVD). This study analysed the distribution of doses per fraction based on the fluence map recorded by the electronic portal imaging device (EPID) of the patient's transit dose. This research examined cases involving the cervix, breast, and nasopharynx. Transit dose analysis was performed by calculating the gamma index (GI) with composite and field-by-field methods. The gamma passing rate (GPR) value was assessed for its correlation with the subject's body weight. In the case of the nasopharynx, breast, and cervix, the GPR value decreased as the fraction increased. In the case of the nasopharynx, the correlation between the GPR and fraction radiotherapy showed no difference when using either composite or field-by-field methods. However, in cases involving the cervix and breast, there was a difference in the correlation values between the composite and field-by-field methods, where the subject had a significant correlation (p< 0.05) when it was done using a field-by-field method. In addition, the nasopharynx had the highest number of subjects with significant correlation (p< 0.05) between GPR and body weight, followed by the cervix and breast. In the nasopharynx, breast, and cervix, the reproducibility of the dose distribution decreased. This decreased reproducibility was associated with changes in body weight.
More Related Videos
07:57Positron Emission Tomography-based Dose Painting Radiation Therapy in a Glioblastoma Rat Model using the Small Animal Radiation Research Platform
Published on: March 24, 2022
10:23Author Spotlight: A Machine-Vision Approach to Transmission Electron Microscopy Workflows, Results Analysis and Data Management
Published on: June 23, 2023
Related Concept Videos
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Methods for Studying Drug Absorption: In situ
The Doluisio method involves perfusing a prepared segment of a rat's small intestine with a solution of radiolabeled drug and a non-absorbable marker. This helps to differentiate between absorbed and non-absorbed drug concentrations. The intestinal segment is connected at both ends using tubing and syringes,...