Related Experiment Video
Updated: Jul 23, 2025

Measurement of Outgassing Rates of Steels
Published on: December 13, 2016
Estimation of Cooling Rate of High-Strength Thick Plate Steel during Water Quenching Based on a Dilatometric
Hyo-Haeng Jo1, Kyeong-Won Kim1, Hyungkwon Park1
1Korea Institute of Materials Science, Changwon 51508, Republic of Korea.
Abstract:
The microstructure and hardness along the thickness direction of a water-quenched, high-strength thick plate with a thickness of 40 mm were investigated with three specimens from the thick plate: surface, 1/4t, and 1/2t (center) thickness, and the phase transformation behavior of the thick plate according to the cooling rate was analyzed through dilatometric experiments. Finally, the cooling rate for each thickness of the thick plate was estimated by comparing the microstructure and hardness of the thick plate along with the thickness with those of the dilatometric specimens. Martensite microstructure was observed on the surface of the water-quenched thick plate due to the fast cooling rate. On the other hand, an inhomogeneous microstructure was transformed inside the thick plate due to the relatively slow cooling rate and central segregation of Mn. A small fraction of bainite was shown at 1/4t thickness. A banded microstructure with martensite and bainite resulting from Mn segregation was developed at 1/2t; that is, the full martensite microstructure was transformed in the Mn-enriched area even at a slow cooling rate due to high hardenability, but a bainite microstructure was formed in the Mn-depleted area owing to relatively low hardenability. A portion of martensite with fine cementite at the surface and 1/4t was identified as auto-tempered martensite with a Bagaryatskii orientation relationship between the ferrite matrix and cementite. The microstructure and hardness as well as dilatation were investigated at various cooling rates through a dilatometric experiment, and a continuous cooling transformation (CCT) diagram was finally presented for the thick plate. Comparing the microstructure and hardness at the surface, 1/4t, and 1/2t of the thick plate with those of dilatometric specimens cooled at various cooling rates, it was estimated that the surface of the thick plate was cooled at more than 20 °C/s, whereas the 1/4t region was cooled at approximately 5~10 °C/s during water quenching. Despite the difficulty in estimation of the cooling rate of 1/2t due to the banded structure, the cooling rate of 1/2t was estimated between 3 and 5 °C/s based on the results of an Mn-depleted zone.
Related Concept Videos
Fluid Pressure over Curved Plate of Constant Width
Temperature Dependent Deformation
Mechanical Characteristics of Steel
The tension test is fundamental for determining tensile strength. In this test, a steel specimen is stretched using a gripping device until it breaks. The data collected during this test are used...
Fluid Pressure over Flat Plate of Variable Width
The pressure distribution on the plate can be calculated by determining the force that acts on a differential area strip of the plate. Thus, the magnitude of the force is equal to the...
Fluid Pressure over Flat Plate of Constant Width
The resultant force...