Related Experiment Video
Updated: Jul 23, 2025

Drug-Induced Sleep Endoscopy DISE with Target Controlled Infusion TCI and Bispectral Analysis in Obstructive Sleep Apnea
Published on: December 6, 2016
Time Spent with Saturation below 80% versus 90% in Patients with Obstructive Sleep Apnoea
András Bikov1,2, Stefan Frent3, Oana Deleanu4
1Wythenshawe Hospital, Manchester University NHS Foundation Trust, Manchester Academic Health Science Centre, Oxford Road, Manchester M13 9WL, UK.
Background:
Nocturnal hypoxaemia measured as the percentage of total sleep time spent with saturation below 90% (TST90%) may better predict cardiovascular consequences of obstructive sleep apnoea (OSA) than the number of obstructive respiratory events measured with the apnoea-hypopnea index (AHI). Deeper hypoxaemia may potentially induce more severe pathophysiological consequences. However, the additional value of the percentage of total sleep time spent with saturation below 80% (TST80%) to TST90% is not fully explored.
Methods:
Comprehensive medical history was taken and fasting lipid and C-reactive protein levels were measured in 797 volunteers participating in two cohort studies in Hungary and Romania. Sleep parameters, including AHI, TST90% and TST80%, were recorded following a polysomnography (PSG, n = 598) or an inpatient cardiorespiratory polygraphy (n = 199). The performance of TST80% to predict cardiovascular risk was compared with TST90% using linear and logistic regression analyses as well receiver operating characteristics curves. Sensitivity analyses were performed in patients who had PSG, separately.
Results:
Both parameters are significantly related to cardiovascular risk factors; however, TST80% did not show better predictive value for cardiovascular risk than TST90%. On the other hand, patients with more severe hypoxaemia reported more excessive daytime sleepiness.
Conclusions:
TST80% has limited additional clinical value compared to TST90% when evaluating cardiovascular risk in patients with OSA.
Related Concept Videos
Sleep Apnea
The condition is more prevalent among...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Pulse Oximetry
Purpose
Average SpO2 values are greater than 95%. If the readings fall below 90%, it indicates that...
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this...
Oxygen Delivering System I: Nasal Cannula and Face Mask
Nasal Cannula
A nasal cannula is a lightweight tube split at one end into two prongs and placed in the nostrils. It is typically used to deliver low to medium levels of oxygen.
Suggested flow rate: The suggested flow rate for a nasal cannula typically ranges between 1 and 6 L/min.
Oxygen percentage setting:...
Respiratory Volumes and Capacities I

