Related Experiment Video
Updated: Jul 23, 2025

A Rapidly Incremented Tethered-Swimming Maximal Protocol for Cardiorespiratory Assessment of Swimmers
Published on: January 28, 2020
A Rigorous and Integrated On-Water Monitoring System for Performance and Technique Improvement in Rowing
Thanassis Mpimis1, Vassilis Gikas1, Vassilios Gourgoulis2
1School of Rural, Surveying and Geoinformatics Engineering, National Technical University of Athens (NTUA), 15780 Zografos, Greece.
Abstract:
This paper presents a prototype, on-water rowing monitoring system and its testing results for a single scull boat. The proposed system aims at recording critical kinetic (athlete biomechanics and oar/seat movements) and kinematic (boat position, velocity, acceleration, and attitude) parameters for sport performance evaluation and rowing technique improvement. The data acquisition unit is organized in two parts: the first part aims at logging boat kinematics based on GNSS/INS filtering, while the second one facilitates kinetics data recording using a series of analog sensors (potentiometers, strain gauges) installed on the athlete's body and the boat seat and oars. Both parts are connected to a central unit featuring analog voltage digitizers and a micro-PC for device handling and data storing. In order to test the performance of the system a series of field trials were undertaken featuring different observation scenarios as well as intentionally induced errors in the rowing technique. Analysis revealed the high performance of the system in terms of sensor completeness and setup procedures as well as operational efficiency. Moreover, system performance evaluation exercised through studying raw data recordings and resultant parameters at stroke cycle and average (standardized) stroke cycle level confirmed the fruitfulness of the proposed approach and system and its potential for implementation on a broad scale. Finally, the data acquired from the proposed system were used to compute the adopted input parameters and performance indicators to characterize the system in terms of functionality and operational efficiency.
More Related Videos
05:58Author Spotlight: Advancing Coral Culture - Creating a Semi-Quantitatively Controlled Microenvironment System to Counter Current Limitations
Published on: July 21, 2023
12:50Continuous Instream Monitoring of Nutrients and Sediment in Agricultural Watersheds
Published on: September 26, 2017
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Pulse rhythm
Conversely, an irregular pulse pattern is termed dysrhythmia, stemming from disruptions in cardiac...
Testing Water Quality
Buoyancy and Stability for Submerged and Floating Bodies
Holter Monitor: 24-Hour Monitoring
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment: