Monitoring and Analysis of the Collapse Process in Blasting Demolition of Tall Reinforced Concrete Chimneys
Xiaowu Huang1,2, Xianqi Xie1,2, Jinshan Sun2
1College of Science, Wuhan University of Science and Technology, Wuhan 430065, China.
Abstract:
Aiming at the problem of displacement of collapse direction caused by the impact of the high-rise reinforced concrete chimney in the process of blasting demolition, combined with the monitoring methods such as high-speed photography observation, piezoelectric ceramic sensor, and blasting vibration monitor, the impact process of the 180 m high chimney was comprehensively analyzed. The results show that the chimney will experience multiple 'weight loss' and 'overweight' effects during the sit-down process, inducing compressive stress waves in the chimney. When the sit-down displacement is large, the broken reinforced concrete at the bottom can play a significant buffering effect, and the 'overweight' effect gradually weakens until the sit-down stops. The stress of the inner and outer sides of the chimney wall is obviously different in the process of collapsing and touching the ground. The waveform of the monitoring point of the piezoelectric ceramic sensor is divided into three stages, which specifically characterizes the evolution process of the explosion load and the impact of the chimney. The vibration induced by explosive explosion is mainly high-frequency vibration above 50 Hz, the vibration induced by chimney collapse is mainly low-frequency vibration below 10 Hz, and the vibration characteristics are obviously different. In the process of blasting demolition and collapse of high-rise reinforced concrete chimney, due to the impact of sitting down, the wall of the support tube is subjected to uneven force, resulting in the deviation of the collapse direction. In practical engineering, the control measures of chimney impact, blasting vibration, and collapse touchdown vibration should be fully strengthened to ensure the safety of the protection target around the blasting demolition object.
Related Concept Videos
Reinforced Brick Masonry
To fortify brick walls...
Microcracking in Concrete
Shrinkage in Concrete
When concrete is still in its plastic state, it can undergo a decrease in volume by about 1% of its absolute volume. This decrease is known as plastic shrinkage. It arises either...
Measurement of Air Content in Concrete
The pressure method,...
Non-destructive Tests for Concrete Strength
Slump Test
Concrete is poured into the mold in three layers to conduct the test. Each layer is compacted 25 times with a steel tamping rod, which has a five-eighths-inch diameter and a rounded end, to ensure even distribution and eliminate...