An electronic stethoscope is judged better than conventional stethoscopes for anesthesia monitoring
Abstract:
A prototype electronic monitoring stethoscope was constructed from readily available, high-quality components. It consisted of a conventional precordial or esophageal probe connected to a microphone by a rubber adapter. The microphone was connected by lightweight wire to an amplifier and headphones. Twenty-one anesthesia clinicians evaluated the stethoscope and responded to a multiple-choice preference questionnaire. The electronic stethoscope was judged to perform better than the conventional stethoscope in most categories evaluated. The electronic device was perceived to be louder, clearer in sound reproduction, more efficacious for monitoring, and easier to use continuously, and its headphones were considered more comfortable than the conventional earpiece. Based on our results, we conclude that amplified stethoscopes have the potential to improve monitoring. Further development of electronic stethoscope monitoring seems warranted and is continuing.
More Related Videos
14:52Recording Brain Electromagnetic Activity During the Administration of the Gaseous Anesthetic Agents Xenon and Nitrous Oxide in Healthy Volunteers
Published on: January 13, 2018
06:57Use of an Integrated Low-Flow Anesthetic Vaporizer, Ventilator, and Physiological Monitoring System for Rodents
Published on: July 9, 2020
Related Concept Videos
Assessment of apical pulse
Assessing the apical pulse is a critical nursing procedure, particularly indicated for:
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Instrumentation Amplifier
To overcome this challenge, an ECG machine utilizes an instrumentation amplifier. This specialized amplifier is...
Stages of General Anesthesia